<?xml version="1.0" encoding="UTF-8"?>
<rss  xmlns:atom="http://www.w3.org/2005/Atom" 
      xmlns:media="http://search.yahoo.com/mrss/" 
      xmlns:content="http://purl.org/rss/1.0/modules/content/" 
      xmlns:dc="http://purl.org/dc/elements/1.1/" 
      version="2.0">
<channel>
<title>Microfluidic Future</title>
<link>https://www.microfluidicfuture.com/index.html</link>
<atom:link href="https://www.microfluidicfuture.com/index.xml" rel="self" type="application/rss+xml"/>
<description>A blog on advances in microfluidics</description>
<generator>quarto-1.3.450</generator>
<lastBuildDate>Mon, 04 Mar 2013 00:00:00 GMT</lastBuildDate>
<item>
  <title>Continuously Sorting Particles According to Shape</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/inertial-focusing/index.html</link>
  <description><![CDATA[ 




<p>There are numerous filters to separate particles in liquid based on their size, which can be enough to isolate them; however, particle shape can be more important, as it distinguishes healthy red blood cells from those affected by sickle-cell disease or malaria. Shape can also be used to determine what stage a cell is in of the cell cycle, which would benefit researchers looking for dividing cells. Recent research by <a href="http://biomicrofluidics.com/">Dino Di Carlo</a> of UCLA looks to separate particles of differing aspect ratios continuously, using inertial fluid-dynamics. His work, “Continuous Inertial Focusing and Separation of Particles by Shape,” featured in <a href="http://prx.aps.org/abstract/PRX/v2/i3/e031017">Physical Review X</a> reminds me of his previous work to use <a href="../../blog/vortices-not-vortexing-replacing-the-centrifuge-with-a-lab-on-a-chip/index.html">inertial fluid-dynamics to continuously filter particles according to size</a>.</p>
<section id="particle-separation" class="level2">
<h2 class="anchored" data-anchor-id="particle-separation">Particle Separation</h2>
<p>Existing methods to separate particles according to shape include hydro-dynamic filtration (HDF) and deterministic lateral displacement (DLD), along with a few others. DLD involves a grid of posts in a channel that is arranged in a way that effectively separates particles according to size. This can be enhanced by controlling particle orientation in order to filter by particle shape or shear stress to separate by particle deformability. HDF uses highly branched channels to separate particles by size according to the fluidic resistance of the side channels. Both of these methods are passive and continuous, but they have highly complex structures and require low flow rates (no greater than a few µL/min). Di Carlo’s method uses fluid inertia to focus particles in channels at high flow rates from 40 to 80 µL/min. This utilizes a shear-gradient lift force and a wall-effect lift force in order to shift particles across streamlines when the Reynolds number of the particle is on the magnitude of 1 or greater. The shear-gradient lift force is directed down the shear gradient and toward the wall, while the wall-effect lift force is caused by the wake of a particle near the wall and is directed away from the wall. With a Reynolds numbers on the order of 1, inertial lift forces dominate the particle behavior while viscous interactions dominate when the particle Reynolds number is &lt;&lt; 1. As the particle Reynolds number increases, migration across streamlines, away from the center line, is observed.</p>
<p>Di Carlo attempted to separate spheres and ellipsoids of varying aspect ratios, while conserving volume. Spheres of 3 µm and 6 µm in diameter, and ellipsoids that conserved the volume at 1:3 and 1:5 aspect ratios were used.</p>
</section>
<section id="results" class="level2">
<h2 class="anchored" data-anchor-id="results">Results</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 55.0%;justify-content: center;">
<p>This work demonstrates that rod-like particles find equilibrium positions close to the center of the channel, while spheres of the same volume end up in streamlines close to the wall. When the major axis of the particles rotates perpendicular to the plane of the wall, the wall-effect lift increases and the particles is pushed away from the wall. Once the major axis has realigned with the direction of the flow, the wall-effect lift decreases and the particles move towards the wall one again. However, particles with higher aspect ratios experience a wall-effect lift greater than the shear-gradient lift and find equilibrium positions closer to the center of the channel. As the Reynolds number of the particle increases (increasing flow rate is one way to increase Reynolds number), the shear-gradient lift force increases faster than the wall-effect lift force. But the particles with higher aspect ratios rotate and experience a greater wall-effect lift force and return to the center. This relationship with increasing particle Reynolds number allows this method to scale with flow rate, while the previous methods do not.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 45.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/inertial-focusing/Channel.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Spheres and ellipsoids are sorted using inertial fluid-dynamics. Particles with larger aspect radios reach equilibrium positions (Xeq) 4 cm downstream.</figcaption>
</figure>
</div>
</div>
</div>
</div>
<p>Four different shape-activated particle-sorting (SAPS) devices were designed with varying numbers of outlets, outlet resistances, channel aspect ratios and flow rates. Three of the devices used 6 µm spheres and their derived ellipsoids, while the final device used the 3 µm particles. All of the devices had varying performances, but the researchers selected device C, which had 7 outlets and isolated 88% of the spheres with 87% purity, 49% of 1:5 rods with 78% purity and 77% of 1:3 rods with 80% purity, for sorting yeast cells. Yeast cells are normally spherical, but form a bispherical twin or aggregate when budding. This change in shape is similar to the varying aspect ratios examined previously. It is useful to synchronize cell cycle stages, but this may be achieved with chemicals that alter cell physiology, changes in temperature or size filtration. SAPS C was able to extract nondividing singles with high yield and purity up to 94% and 54% of budded yeast cells were recovered at 31% purity, which increased from 6.6% purity at the inlet. According to my rough measurements from the paper’s figures, the aspect ratio of budding yeast is less than 2:1 which may explain the difference in performance compared to the original ellipsoids. Previously, Sugaya et al. used a 5 outlet HDF system to separate budding yeast cells. In comparison, Sugaya achieved up to 69.4% purity of budding cells in one outlet, up from 39.4% at the inlet. This same outlet recovered 28.8% of budding cells while another outlet recovered 65.2%. There is still room for improvement of Di Carlo’s budding yeast yield, but this operated at 1500 cell/s, compared to 100 cell/s from previous work that utilized dielectrophoretic forces according to the opacity of dividing yeast.</p>
</section>
<section id="future-work" class="level2">
<h2 class="anchored" data-anchor-id="future-work">Future Work</h2>
<p>Di Carlo has proposed that this work be used to sort shaped particles in other areas to improve cytometry that operates on spherical particles, alignment of <a href="http://dx.doi.org/10.1126/science.1134929">barcoded particles</a>, and identification of microalgae that vary in size and shape. Interestingly, he also introduced the capability of this setup for a non-biological process: improving cement. Cement strength and stability are affected by particle shape and size and could benefit from shape based separation. According to Dr.&nbsp;Di Carlo, “… [Cement] particles that are too large may not react completely in internal regions of the particle, while smaller particles with very high surface area to volume ratios can react too quickly and may not be stable.” I’m excited to see microfluidics expand into more established industries and further demonstrating real-world potential to be a more cost effective, accessible technology.</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-panel quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Masaeli, M., Sollier, E., Amini, H., Mao, W., Camacho, K., Doshi, N., Mitragotri, S., Alexeev, A., &amp; Di Carlo, D. (2012). Continuous Inertial Focusing and Separation of Particles by Shape <span style="font-style: italic;">Physical Review X, 2</span> (3) DOI: <a href="http://dx.doi.org/10.1103/PhysRevX.2.031017">10.1103/PhysRevX.2.031017</a></p>
</div>
</div>
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Di Carlo, D., Irimia, D., Tompkins, R., &amp; Toner, M. (2007). Continuous inertial focusing, ordering, and separation of particles in microchannels <span style="font-style: italic;">Proceedings of the National Academy of Sciences, 104</span> (48), 18892-18897 DOI: <a href="http://dx.doi.org/10.1073/pnas.0704958104">10.1073/pnas.0704958104</a></p>
</div>
</div>
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Sugaya, S., Yamada, M., &amp; Seki, M. (2011). Observation of nonspherical particle behaviors for continuous shape-based separation using hydrodynamic filtration <span style="font-style: italic;">Biomicrofluidics, 5</span> (2) DOI: <a href="http://dx.doi.org/10.1063/1.3580757">10.1063/1.3580757</a></p>
</div>
</div>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Dino Di Carlo</category>
  <category>Lab on a Chip</category>
  <category>RSC Lab on a Chip</category>
  <category>UCLA</category>
  <guid>https://www.microfluidicfuture.com/blog/inertial-focusing/index.html</guid>
  <pubDate>Mon, 04 Mar 2013 00:00:00 GMT</pubDate>
</item>
<item>
  <title>Tracking Immune Responses to Food with a Gut on a Chip</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/nutrichip/index.html</link>
  <description><![CDATA[ 




<section id="organs-on-chips" class="level2">
<h2 class="anchored" data-anchor-id="organs-on-chips">Organs on Chips</h2>
<p>In an effort to model the complex processes occurring in human bodies, <a href="http://wyss.harvard.edu/viewpage/121/donald-e-ingber">Donald Ingber</a> has pioneered the development of ‘<a href="http://wyss.harvard.edu/viewpage/293/">organs-on-chips</a>,’ reproducing the lung and the gut on microfluidic devices. These systems allow researchers to replicate and study organs without the use of human test subjects. While this is one of the best options, there are too many variables to control, understand, and more importantly, manipulate. At the other end of the spectrum is an <em>in vitro</em> study with a cell line and few variables that hardly resemble the real environment. <a href="http://lmis2.epfl.ch/">Researchers in Switzerland</a> have developed their own gut-on-a-chip that imitates a human gastrointestinal tract called the Nutrichip. They hope to use this microfluidic device to study the immune-modulatory function of food (with a strong focus on dairy food). This work is detailed in the article “NutriChip: Nutrition Analysis Meets Microfluidics,” which appears in <a href="http://pubs.rsc.org/en/content/articlelanding/2013/lc/c2lc40845g">Lab on a Chip</a>.</p>
</section>
<section id="device-aims" class="level2">
<h2 class="anchored" data-anchor-id="device-aims">Device Aims</h2>
<p>The Nutrichip is primarily focused on analyzing the presence and kinetics of inflammatory biomarkers after a meal, which should shed insight on how certain foods impact our bodies. For example, milk products not only provide nutrients, but affect our physiological functions via bacteria, proteins and bioactive peptides. In particular these agents may modulate the fabrication of pro-inflammatory cytokines, which the Nutrichip aims to monitor. The Nutrichip mimics the thin layer of epithelial cells of the intestinal tract and the immune system it interacts with. In this system, the epithelial cells transport nutrients into circulation to be metabolized by the body, and the immune system controls responses to any trespassing pathogenic organisms. Not only do epithelial cells try to keep out pathogens, but they must filter what reaches the immune layer in order to maintain immunological tolerance to nutrients.</p>
</section>
<section id="device-design" class="level2">
<h2 class="anchored" data-anchor-id="device-design">Device Design</h2>
<p>The device is composed of three distinct parts, an apical layer, a basolateral layer, and a membrane which separates them. The apical layer is populated with a culture of intestinal epithelial cells. In this model, the authors used Caco-2 cells to produce a confluent layer of the intestine. This cell line is derived from a human colorectal adenocarcinoma that demonstrates most of the morphological and functional traits of intestinal cells. The basolateral layer contains a culture of monocytic cell line differentiated into macrophages. A chamber downstream of the monocytes contains magnetic beads functionalized with antibodies against the targeted cytokines. These beads allow <em>in situ</em> capture and washing of the cytokines before fluorescent detection.</p>
</section>
<section id="experimental-procedure-and-results" class="level2">
<h2 class="anchored" data-anchor-id="experimental-procedure-and-results">Experimental Procedure and Results</h2>
<p>The researchers treated the apical layer with tumor necrosis alpha (TNFα) and lipopolysaccharide (LPS), which is found in the membrane of Gram-negative bacteria, for 24 hours. This resulted in a significant secretion of the cytokine Interleukin 6 (IL-6) in the basolateral media. However, the Caco-2 cells protected the macrophages very well, as the LPS concentration applied to the apical layer resulting in a response, was three orders of magnitude greater than that would be applied to the basolateral layer directly to produce the same cytokine response. When the macrophages were treated directly with LPS, there was a significant increase in IL-6 which indicates that they may be able to quantify the IL-6 with their proposed magnetic beads. These two experiments indicate that they can partially mimic the intestinal tract and monitor the effect that certain compounds or nutrients have on the body’s immune system.</p>
</section>
<section id="thoughts-on-future-work" class="level2">
<h2 class="anchored" data-anchor-id="thoughts-on-future-work">Thoughts on Future Work</h2>
<p>This is all very preliminary work, and the researchers hope to measure the pro-inflammatory activity of meals, anti-inflammatory activity of dairy products as well the bio-availability of nutrients in digested foods. To make that final component a reality, they also intend to include on-chip digestion capabilities. I am sure there are alternatives to a dynamic digestive tract moving bolus through the system, but I’d love to see it anyway. I think this work could be extremely beneficial in understanding food allergies. We seem to have more food allergies these days that may be due to changes in modern life or may have gone undetected previously (or is perhaps just over diagnosed).</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Ramadan, Q., Jafarpoorchekab, H., Huang, C., Silacci, P., Carrara, S., Koklü, G., Ghaye, J., Ramsden, J., Ruffert, C., Vergeres, G., &amp; Gijs, M. (2013). NutriChip: nutrition analysis meets microfluidics Lab on a Chip, 13 (2) DOI: <a href="http://dx.doi.org/10.1039/c2lc40845g">10.1039/c2lc40845g</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>RSC Lab on a Chip</category>
  <category>Immunology</category>
  <category>Lab on a Chip</category>
  <category>Ecole Polytechnique Federale de Lausanne</category>
  <guid>https://www.microfluidicfuture.com/blog/nutrichip/index.html</guid>
  <pubDate>Wed, 20 Feb 2013 00:00:00 GMT</pubDate>
</item>
<item>
  <title>A Microsyringe to Take the Pain out of Shots</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/microsyringe/index.html</link>
  <description><![CDATA[ 




<p>Back when I was in sixth grade, I remember reading a little blurb in some science magazine at school that in the future we could receive shots via a method that would feel as soft as a banana peel. Although I’m now a champ at taking shots, it’s still not a bad idea. We’ve had transdermal patches (think nicotine and birth control) for some time now, but those release their medicine over a period of time. A syringe is capable of delivering a dose at once, and can take a biological sample too. Researchers from the University of Pisa have developed this ‘syringe of the future’ within ‘<a href="http://pubs.rsc.org/en/content/articlelanding/2012/LC/c2lc40348j">A minimally invasive microchip for transdermal injection/sampling applications</a>’ in Lab on a Chip.</p>
<section id="microsyringe-design" class="level2">
<h2 class="anchored" data-anchor-id="microsyringe-design">Microsyringe Design</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 55.0%;justify-content: center;">
<p>The microsyringe is actually a 0.5 cm x 0.5 cm microchip featuring thousands of hollow silicon-dioxide microneedles. The microneedles are 100 µm long at a density of 1 million needles/cm<sup>2</sup>. These needles are at least 100 times denser and 10 times smaller than other results reported in the literature. Furthermore, this is not simply a design for microneedles; the researchers have incorporated a reservoir that is meant to store samples from the body and medicine when injecting. The reservoir is comprised of 14 independent volumes adding up to 4.2µL with a sealed plastic cap. The microsyringe would not penetrate as deeply as a normal syringe and would have a smaller total cross-sectional area, resulting in a less painful injection. The researchers intend this microsyringe to be an integral part of an artificial pancreas that is capable of continuously sampling interstitial fluids, measuring glucose levels and releasing insulin to regulate glucose in the blood.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 45.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/microsyringe/Microsyringe_demo.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Fabricated 0.25 cm2&nbsp;microsyringe showing (a)&nbsp; needles and (b) reservoirs on reverse.</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="microsyringe-theoretical-analysis" class="level2">
<h2 class="anchored" data-anchor-id="microsyringe-theoretical-analysis">Microsyringe Theoretical Analysis</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 55.0%;justify-content: center;">
<p>If the microsyringe is going to be used in the real world, the microneedles need to be able to puncture the outer layers of the skin without breaking. They first tested this theoretically by analyzing the forces acting on the microneedles during insertion. The force required to pierce the skin (derived from a known skin-piercing pressure and the known area of the microsyringe) are compared to the maximum values of the buckling and bending forces that the microneedles would encounter. The buckling force would arise when the microneedle insertion is misaligned with respect to its axis of symmetry (in other words, when the skin isn’t orthogonal to the microneedle cross-section). The bending force is generated by lateral movement between the tissue and needle during the beginning of insertion. The theoretical analysis reveals that the buckling and bending forces are at least 10 times greater than the piercing force, giving it a factor of safety greater than 10.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 45.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/microsyringe/Microsyringe_schematic.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Schematic of microsryinge illustrates the array of needles connecting to independent reservoirs on reverse.</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="microsyringe-mechanical-testing" class="level2">
<h2 class="anchored" data-anchor-id="microsyringe-mechanical-testing">Microsyringe Mechanical Testing</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 55.0%;justify-content: center;">
<p>The researchers followed up this theoretical analysis by simulating insertion into human skin using agarose gel models, which have mechanical properties similar to those of skin. The microsyringes were inserted into the skin at 200 and 500 gram-forces (typical force produced by finger) for 30, 60 and 120 seconds. After repeated insertion tests of the same microneedles, the researchers found that they all penetrated successfully without significant damage to the needles (characterization by SEM). Since this device needs to be able to store liquid, they tested losses due to evaporation and acceleration (ie dropping). Over a 19 day test period, they measured an evaporation rate of 71 nL/min through the microneedles, which would drain the reservoir in an hour. Under acceleration of 80g, the microneedles lost 1320 nL/min, which would drain the reservoir in 3 minutes of falling.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 45.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/microsyringe/Microsyringe_SEM.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">SEM of fabricated microsyringe illustrating the density and uniformity of the needles.</figcaption>
</figure>
</div>
</div>
</div>
</div>
<p>I wonder how the use of this microsyringe would actually work. 4.2 µL is small to begin with, but each individual reservoir is 0.3 µL. It’ll be difficult to load medicine and collect samples. I’m really interested in the group’s plan to use it in an artificial pancreas. A microsyringe by itself is good, but I love the idea of a pancreas. I suppose that one of the most important aspects of the microsyringe is its reservoir size. What’s a relevant medicine payload? What sample size is needed for analysis? I think this is some promising research from this group, and I look forward to reading about their pancreas.</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Strambini LM, Longo A, Diligenti A, &amp; Barillaro G (2012). A minimally invasive microchip for transdermal injection/sampling applications. Lab on a chip, 12 (18), 3370-9 PMID: <a href="http://www.ncbi.nlm.nih.gov/pubmed/22773092">22773092</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Lab on a Chip</category>
  <category>Hematology</category>
  <category>RSC Lab on a Chip</category>
  <guid>https://www.microfluidicfuture.com/blog/microsyringe/index.html</guid>
  <pubDate>Wed, 03 Oct 2012 00:00:00 GMT</pubDate>
</item>
<item>
  <title>Studying the Effects of Confinement on Cell Division</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/forcing-multi-daughter-cell-division/index.html</link>
  <description><![CDATA[ 




<p>On <em>Microfluidic Future</em> I like reviewing advancements in therapeutic or diagnostic devices because I’m really drawn to those areas of research. Every once in a while, however, I take interest in research for the sake for knowledge, like the <a href="../../blog/getting-to-the-root-of-microfluidics/index.html">Root Chip</a>. I recently came across an article from <a href="http://dicarlo.bol.ucla.edu/">Dino Di Carlo of UCLA</a> that describes a microfluidic device used to study cancer cells. The article, “Increased Asymmetric and Multi-Daughter Cell Division in Mechanically Confined Microenvironments” appeared in <a href="http://www.plosone.org/article/info:doi/10.1371/journal.pone.0038986">PLoS ONE</a>, which is an open access journal (very cool!).</p>
<p>Specifically, Di Carlo’s device is used to study the effects of the mechanical environment on cancer cells during division. It’s commonly known that the course of the cell cycle is affected by soluble factors, but the cell’s mechanical interaction with the environment also affects its morphology, differentiation and cell cycle. Changes in confinement and substrate elasticity were tested using the HeLa cervical cancer cell line in this study. The authors looked for several deviations from standard cell division including delayed mitosis, multi-daughter mitosis events, unevenly sized daughter cells and induction of cell death.</p>
<section id="device-design" class="level2">
<h2 class="anchored" data-anchor-id="device-design">Device Design</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 55.0%;justify-content: center;">
<p>Di Carlo’s device has a bottom layer and an elevated PDMS layer supported by posts with varying height for control over cell confinement. In a relaxed state, there is a 15 µm clearance between the posts and bottom layer. When pressure is applied to the device, the two layers meet which confines the cells between posts and reduces the clearance to 3 µm or 7 µm. Additionally, the top layer has an elasticity of 130 KPa or 1 MPa. The device is designed to allow media to flow throughout all the confining chambers, eliminating the possibility of cell death due to a toxic environment.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 45.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/forcing-multi-daughter-cell-division/Confined_Cell_Schematic.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">A. The device features posts to confine cells with continuous perfusion. B. The device is deformable, bringing the two layers into contact. C. The device has variable elasticity and confinement height.</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="results" class="level2">
<h2 class="anchored" data-anchor-id="results">Results</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 55.0%;justify-content: center;">
<p>In an unconfined environment, a HeLa cell would normally ball up into a sphere during mitosis, which would take no longer than 140 minutes. But with increased confinement and stiffness, the authors witnessed multi-daughter mitosis (one cell dividing into three or four daughter cells), unbalanced daughter sizes, prolonged mitosis and cell death. Resulting control cells from division would often be spheres with a diameter of 20 µm, while the confined cells would be highly asymmetric with diameters 40-80 µm. Increases in stiffness and confinement generally increased the odds of abnormal cell division, with some clear observed patterns. Under low compression of 7µm and stiffness of 130 KPa, 90% of multi-daughter divisions resulted in three cells. When a stiffness of 1 MPa was applied to the same low compression, 85% of multi-daughter divisions resulted in four cells. The authors believe that the cells aren’t able to effectively deform the stiffer substrate and are limited in how spherical they can be before mitosis. The confined shape may also affect chromosomes lining up at the metaphase plane(s), resulting in a bias toward multi-daughter divisions. The multi-daughter cell divisions can produce viable cells, which subsequently can undergo their own multi-daughter division, and also generate daughters that re-fuse after division.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 45.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/forcing-multi-daughter-cell-division/Multi-Daughter_Division.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Induced multi-daughter division resulted in 3, 4 and even 5 daughters</figcaption>
</figure>
</div>
</div>
</div>
</div>
<p>The authors also hypothesized that when the cells are forced to divide in a discoid shape, signaling and regulation may be affected. Diffusion or active transport of signals would take much longer to traverse the large cross-section of the cell, and the force of cytoskeletal elements might be diminished across the same large distance.</p>
</section>
<section id="discussion" class="level2">
<h2 class="anchored" data-anchor-id="discussion">Discussion</h2>
<p>This work has produced some findings that may not be totally surprising, but are definitely peculiar. A follow-up to the findings generated here would surely add to the increasing knowledge base of cancer cell behavior. In its current form, this information wouldn’t lead to any new treatments, although under high confinement 70% of cell cycles resulted in cell death, which holds potential in therapeutic applications. Studying diseases help us learn more about healthy cells because we can see what goes wrong when specific elements fail, but I’m also interested in seeing how healthy cells react under the same mechanical conditions. The microfluidic device itself also has potential beyond the study of cellular life cycles: One area in particular includes investigating the effects of mechanical strain in osteocyte and chondrocyte differentiation.</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Henry Tat Kwong Tse, Westbrook McConnell Weaver, &amp; Dino Di Carlo (2012). Increased Asymmetric and Multi-Daughter Cell Division in Mechanically Confined Microenvironments PLoS ONE, 7 (6)</p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Oncology</category>
  <category>Lab on a Chip</category>
  <category>UCLA</category>
  <category>Dino Di Carlo</category>
  <category>PLoS ONE</category>
  <guid>https://www.microfluidicfuture.com/blog/forcing-multi-daughter-cell-division/index.html</guid>
  <pubDate>Tue, 14 Aug 2012 00:00:00 GMT</pubDate>
  <media:content url="https://www.microfluidicfuture.com/blog/forcing-multi-daughter-cell-division/Confined_Cell_tab2.jpg" medium="image" type="image/jpeg"/>
</item>
<item>
  <title>Rolling Out Cell Sorting with Microfluidics</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/rolling-cell-sorting/index.html</link>
  <description><![CDATA[ 




<section id="cell-sorting" class="level2">
<h2 class="anchored" data-anchor-id="cell-sorting">Cell Sorting</h2>
<p>Cells are quite valuable, especially when used for regenerative research, diagnostics or research. But harvested cells do not come presorted and need to be separated from a heterogeneous mixture of cells. There are already numerous methods to sort cells according to biophysical properties such as size, density, morphology, and dielectric or magnetic susceptibility. Cell sorting based on labels can have a higher specificity, but introduces extra steps to add and remove labels, which can affect the phenotype of the cell. <a href="http://web.mit.edu/karnik/www/home.htm">Rohit Karnik</a> of MIT has developed a cell sorting method based on cell rolling. The continuous, label-free process is described in “<a href="http://pubs.rsc.org/en/content/articlelanding/2012/lc/c2lc21225k">Cell sorting by deterministic rolling</a>” in Lab on a Chip.</p>
</section>
<section id="cell-rolling" class="level2">
<h2 class="anchored" data-anchor-id="cell-rolling">Cell Rolling</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 55.0%;justify-content: center;">
<p>Cell rolling is a phenomenon where a cell is constantly forming and releasing adhesive bonds with a surface under fluid flow. The continuous creation and release of bonds by the cell induces rolling and is an integral role in the movement of lymphocytes, platelets, stem cells and metastatic cancer cells. To induce cell rolling, a surface needs to be coated with a ligand specific to the target cell type. The rolling target cells need to be focused, so slanted ridges are added to the bottom of the channel. When the target cell comes into contact with the surface of the coated ridges, it will begin to roll along it and eventually turn the corner into the space between ridges. By following the path of the direction of the ridges, the targeted cells will be focused on one side of the channel known as the gutter. The non-target cells should not adhere and roll along the ridges, allowing them to be spatially differentiated from the target cells. But the ridges actually serve an additional purpose: Acting as mixers, these ridges introduce circulation to the axial flow. This flow would normally be laminar, which would prevent the majority of cells from coming in contact with the surface of the channel and rolling.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 45.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/rolling-cell-sorting/cell_rolling.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Target cells initiate cell rolling and enter the space between the ridges, which leads them to the gutter side. Non-target cells do not adhere or roll along the surface and maintain their original trajectories.</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="cell-rolling-testing-optimization" class="level2">
<h2 class="anchored" data-anchor-id="cell-rolling-testing-optimization">Cell Rolling Testing &amp; Optimization</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 55.0%;justify-content: center;">
<p>Karnik validated this cell sorting method by processing the leukemia cell lines HL60 and K562. The surfaces were coated with P-selectin, which is a known ligand for the target HL60. HL60 and K562 were injected in a single inlet at a ratio of 2:3, respectively. Outlet A held 95.0 ± 2.8% HL60 cells, and outlet B had 94.3 ± 0.9% K562 cells. The cell sorting was extremely successful and 87.2 ± 3.7% and 76.7 ± 14.2% of the HL60 and K562 cells were recovered at the end of the process. Cell loss was most likely due to settling in the syringe at the inlet and cells remaining in the channel and dead volumes at the end of the process. Karnik also investigated the effect of the ligand concentration on cell sorting. Higher concentrations generated stronger cell-surface adhesion, but this came at the expense of cell rolling, so an operating point had to be determined for an ideal cell rolling concentration; at a flow rate of 70 µL/min, the channel was incubated with P-selectin concentration of 1.5 µg/mL.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 45.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/rolling-cell-sorting/cell_rolling_results.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">HL60 (target) and K562 (non-target) cells enter through the same inlet. Due to the cell rolling sorting, the cells exit the two outlets highly organized.</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="discussion" class="level2">
<h2 class="anchored" data-anchor-id="discussion">Discussion</h2>
<p>I really like this method of cell sorting because it is both passive and label-free. Although an extra section of channel must be added with coated ridges, no other major components are necessary. This method does not need any more equipment or chambers, making it simple to integrate into a project. With its small footprint, it can also be highly parallelized, negating the need for it to operate at high flow rates which could hinder cell rolling. This could either function as a standalone sorting device or integrated into a device processing a mixture of cells. Similar to other cell sorting procedures, widespread usage of this particular method is limited to availability of information: only cell lines for which we’ve characterized the rolling behavior for can be sorted this way.</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Choi, S., Karp, J., &amp; Karnik, R. (2012). Cell sorting by deterministic cell rolling <span style="font-style: italic;">Lab on a Chip, 12</span> (8) DOI: <a href="http://dx.doi.org/10.1039/c2lc21225k">10.1039/c2lc21225k</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>RSC Lab on a Chip</category>
  <category>Lab on a Chip</category>
  <category>Rohit Karnik</category>
  <category>MIT</category>
  <guid>https://www.microfluidicfuture.com/blog/rolling-cell-sorting/index.html</guid>
  <pubDate>Wed, 30 May 2012 00:00:00 GMT</pubDate>
</item>
<item>
  <title>Putting the Squeeze on Microfluidics</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/squeeze-chip/index.html</link>
  <description><![CDATA[ 




<p>Microfluidic devices are able to process small volumes of liquid and are comprised of microscale components, but the devices themselves are not often small themselves. These labs-on-chips are often limited to lives in labs instead of the remote areas that could really benefit from their use. The limitation comes in the form of support equipment used to process or analyze assays that are expensive, bulky, energy consuming and/or require trained professional operators. Syringe pumps are often used in labs to drive liquids used in assays at specific flow rates and to ensure that the right volume is used. The need for complicated, external flow equipment was recently addressed by a group from Peking University. The group’s paper, “<a href="http://pubs.rsc.org/en/content/articlelanding/2012/lc/c2lc40125h/">Squeeze-chip: a finger-controlled microfluidic flow network device and its application to biochemical assays</a>” was recently featured on the cover of Lab on a Chip.</p>
<section id="squeeze-chip-design" class="level2">
<h2 class="anchored" data-anchor-id="squeeze-chip-design">Squeeze-chip Design</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 55.0%;justify-content: center;">
<p>The ‘squeeze-chip’ is based on a system of check valves and finger-operated pumps. Check valves allow fluid to flow in only one direction and, in this case, are fabricated from PDMS and integrated into a microfluidic card. The pump is a fluid reservoir that can be depressed by a finger. Squeezing the reservoir evacuates fluid through one of the check valves oriented to pass fluid away from the reservoir. After releasing the reservoir, it draws fluid in through a second check valve that’s oriented in a different direction so that it can only feed liquid into the reservoir. Alternatively, specially designed squeeze-chips can handle two immiscible fluids so that with each pump, a small plug of one fluid can be inserted into the system and is sandwiched by the other fluid. The displaced volume is not always equal, but the reservoirs feed into metering channels which only accept a specific volume, adding some control to the squeeze-chip. The authors have had success in delivering volumes ranging from nanoliters to microliters. This is the basic setup for a squeeze-chip, which can be combined with other units to create a more complex, sophisticated system.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 45.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/squeeze-chip/Squeeze-chip_schematic.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">The squeeze-chip is comprised of two check valves on either side of a reservoir. Squeezing the reservoir pumps fluid through one check valve. The reservoir is refilled after release through the second check valve.</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="squeeze-chip-validation" class="level2">
<h2 class="anchored" data-anchor-id="squeeze-chip-validation">Squeeze-chip Validation</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 55.0%;justify-content: center;">
<p>The researchers demonstrated the squeeze-chip’s ability by running colorimetric assays to measure glucose and uric acid at clinically relevant concentrations of 0-10 mM and 0-15 mM respectively. These assays comprise a system of squeeze-chips that mix solutions, resulting in a 4mm thick readout chamber, allowing the user to see the solution’s color with the naked eye. The researchers were able to detect glucose as low as 1 mM and uric acid as low as 100 µM with initial sample consumption less than 5 µL per test. Limits of detection can be lowered by increasing the readout chamber thickness, which would make the color darker.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 45.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/squeeze-chip/Squeeze-chip_plug_flow.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Alternate design of the squeeze-chip creates liquid sandwiches one fluid in another when immiscible.</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="discussion" class="level2">
<h2 class="anchored" data-anchor-id="discussion">Discussion</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 55.0%;justify-content: center;">
<p>I think that the squeeze-chip is a great component to make devices more viable outside of the lab, though it may not be suitable for every card. The metering chambers add some volume control, but, again, this may not be enough. More importantly, volumetric flow rate isn’t controlled, which eliminates the squeeze-chip as a viable option for applications requiring more stringent regulation. There are several considerations that need to be kept in mind when designing any lab-on-a-chip for use outside the lab. Despite any microscale magic taking place, the end-user and intended environment need elevated priority, meaning that these devices need to be relatively cheap, free of any tethers to an advanced lab and operable by people with limited education. The squeeze-chip certainly addresses cost and eliminates a connection to an external syringe pump. It can be operated by hand, or even operated by an actuated piston if the chip is predestined to function in some housing. Usability testing results would be interesting to see as well, including performance variation among users, but it looks like devices using the squeeze-chip can be readily used in areas of need.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 45.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/squeeze-chip/squeeze-chip.gif" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Sample operation of squeeze-chip used in colorimetric assay.</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="reference" class="level2">
<h2 class="anchored" data-anchor-id="reference">Reference:</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Li, W., Chen, T., Chen, Z., Fei, P., Yu, Z., Pang, Y., &amp; Huang, Y. (2012). Squeeze-chip: a finger-controlled microfluidic flow network device and its application to biochemical assays Lab on a Chip, 12 (9) DOI: <a href="http://dx.doi.org/10.1039/C2LC40125H">10.1039/C2LC40125H</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Lab on a Chip</category>
  <category>RSC Lab on a Chip</category>
  <guid>https://www.microfluidicfuture.com/blog/squeeze-chip/index.html</guid>
  <pubDate>Wed, 02 May 2012 00:00:00 GMT</pubDate>
</item>
<item>
  <title>Diagnosing Similar Diseases in Low Resource Settings</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/diagnosing-similar-diseases/index.html</link>
  <description><![CDATA[ 




<section id="diagnostics-in-low-resource-settings" class="level2">
<h2 class="anchored" data-anchor-id="diagnostics-in-low-resource-settings">Diagnostics in Low-Resource Settings</h2>
<p>A lot of excitement surrounding microfluidics has been about its promising use in diagnosis in low-resource settings. Many infectious diseases present in developing countries are manageable or treatable with available medications, but still account for 1/3 of deaths. In these areas, multiple diseases present similar symptoms, leading to misdiagnosis and thus incorrect treatment. Hundreds of blood-based microfluidic immunoassays are available for diagnostic purposes, but they’re not all created equally. They require varying levels of sample processing or analysis that prohibit their deployment in low-resource settings. Further, while some diseases may have similar symptoms, they might require different detection techniques, with varying sample volumes, reagents and processing time, making it difficult to detect multiple diseases within the same system. This is the focus of recent work from <a href="http://faculty.washington.edu/yagerp/">Paul Yager</a> of University of Washington. In his Lab on a Chip paper, “<a href="http://pubs.rsc.org/en/content/articlelanding/2012/lc/c2lc20751f">Progress toward multiplexed sample-to-result detection in low resource settings using microfluidic immunoassay cards</a>,” he and his colleagues develop a system to detect both Typhoid fever and malaria.</p>
</section>
<section id="malaria-and-typhoid-dual-detection" class="level2">
<h2 class="anchored" data-anchor-id="malaria-and-typhoid-dual-detection">Malaria and Typhoid Dual Detection</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 50.0%;justify-content: center;">
<p>The developed system is intended to integrate with the <a href="http://www.xconomy.com/seattle/2009/11/03/uw-scientists-backed-by-gates-foundation-enter-put-up-or-shut-up-phase-with-portable-diagnostic/">DxBox</a>, an ongoing project focused on a point-of-care diagnostic device. As I mentioned before, different diseases might require different means of detection. In this case, the researchers decided to detect antigens generated by malaria parasites and IgM antibodies generated by the host in response to the bacteria responsible for typhoid (<em>Salmonella</em> Typhi). The microfluidic card is based on a flow-through membrane immunoassay (FMIA) composed primarily of nitrocellulose, instead of traditional microfluidic channels. Nitrocellulose is essentially paper and provides a lot of surface area, creating shorter assay times. Enzyme-linked immunosorbent assays (ELISA) are standard lab assays and will be replicated using FMIA. However, ELISA can be slow (more than 3 hours) due to the diffusion between the bulk fluid and the capture service, while the FMIA can perform the same task in half an hour due to its high surface area.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 50.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/diagnosing-similar-diseases/Card_Design.png" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">The proposed card is compact and intended to integrate with the DxBox. All sample processing occurs on-card including IgG filtration. This also depicts the porous nitrocellulose membrane of the FMIA which provides high assay surface area.</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="immunoassay-process" class="level2">
<h2 class="anchored" data-anchor-id="immunoassay-process">Immunoassay Process</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 50.0%;justify-content: center;">
<p>The detections of both analytes are run in parallel and start with the same unfiltered blood. The card extracts the plasma with a filter, eliminating whole blood cells, and this is where the assays for malaria and typhoid diverge. The typhoid assay must filter out any IgG antibodies (which would cause false positives when testing for IgM) and dilute the sample further. This results in a four-fold increase in the sample volume used in the malaria segment. Each analyte is then captured by immobilized reagents and labeled with gold nanoparticles conjugated to antibodies. The entire process is driven by pneumatic pressure and valves. Pneumatics is cheaper than alternatives, plus it doesn’t dilute the sample with an additional liquid, but it comes at the cost of introduced air bubbles. Air vents were incorporated to eliminate bubbles, but they were not totally eradicated and still obstructed the image analysis sometimes. Within the DxBox, analysis is intended to be carried out by a webcam. However, the current design of the system created nonuniform lighting (which can be rectified), and a flatbed scanner was used instead.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 50.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/diagnosing-similar-diseases/Immunoassay_Process.png" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">The system processes blood from the same sample in different, parallel steps to test for malaria and typhoid.</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="results" class="level2">
<h2 class="anchored" data-anchor-id="results">Results</h2>
<p>This microfluidic card was tested on blood samples with Typhoid or malaria. Unfortunately the researchers did not test on a large enough sample to evaluate clinical utility or determine a limit of detection for the card. Currently lab-based ELISA has a limit of detection near 4 ng/mL, which is clinically relevant. The researchers also ran each sample on ELISA and a bench-top FMIA in addition to the on-card FMIA. Comparing the quantified signal of the on-card FMIA to ELISA resulted in an R<sup>2</sup> value of 0.73, and on-card FMIA vs bench-top FMIA had an R<sup>2</sup> value of 0.92. These are fine results that demonstrate how closely the on-card FMIA follows the bench-top methods, but it would mean a whole lot more given a limit of detection.</p>
</section>
<section id="discussion" class="level2">
<h2 class="anchored" data-anchor-id="discussion">Discussion</h2>
<p>The results of this card design seem promising but will mean a lot more with more testing. The pneumatic actuation was a major hindrance to project success. While they could operate at different pressures, the actuators were unable to actually control the liquid velocity. Also, the pneumatics introduced bubbles into the card, which not only affected the assay process but the final image to be analyzed as well. While only two diseases were showcased here, the authors have indicated that there is already work to create a more complete fever symptom panel. They also acknowledged that this format could be applied to other panels aimed at diarrheal diseases and sexually transmitted diseases as well. This format could really be adapted for a variety of diseases, with the disease diagnosis as the limiting factor for card design.</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Lafleur, L., Stevens, D., McKenzie, K., Ramachandran, S., Spicar-Mihalic, P., Singhal, M., Arjyal, A., Osborn, J., Kauffman, P., Yager, P., &amp; Lutz, B. (2012). Progress toward multiplexed sample-to-result detection in low resource settings using microfluidic immunoassay cards Lab on a Chip, 12 (6) DOI: <a href="http://dx.doi.org/10.1039/C2LC20751F">10.1039/C2LC20751F</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Diagnostics</category>
  <category>Hematology</category>
  <category>Point of Care</category>
  <category>RSC Lab on a Chip</category>
  <category>Immunoassay</category>
  <category>Paul Yager</category>
  <category>Lab on a Chip</category>
  <guid>https://www.microfluidicfuture.com/blog/diagnosing-similar-diseases/index.html</guid>
  <pubDate>Wed, 18 Apr 2012 00:00:00 GMT</pubDate>
  <media:content url="https://www.microfluidicfuture.com/blog/diagnosing-similar-diseases/Immunoassay_Process.png" medium="image" type="image/png" height="74" width="144"/>
</item>
<item>
  <title>Narrowing the Gap to Characterize Sickle Cell Disease</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/characterize-sickle-cell/index.html</link>
  <description><![CDATA[ 




<p>Microfluidic Future is by no means an accurate representation of all the current, ongoing research in microfluidics. Nevertheless, the fact that you won’t be able to find any articles about assays relying on a biophysical marker isn’t too far off the reality in microfluidics. I suppose this is partly due to the incredible amount of previous work on molecular markers when high resolution control hadn’t been realized yet. Regardless, I was happy to come across an article about a microfluidic device that indicates sickle cell disease risk using the disease’s biophysical characteristics. The work “<a href="http://stm.sciencemag.org/content/4/123/123ra26">A Biophysical Indicator of Vaso-occusive Risk in Sickle Cell Disease</a>” appeared in Science Translational Medicine this past February and is a result of ongoing sickle research by MIT and Harvard Medical School. My friend originally forwarded me an article about it on <a href="http://medgadget.com/2012/03/microfluidic-device-measures-underlying-physical-characteristics-of-disease.html">Medgadget</a>, which you should also check out, along with the <a href="http://stm.sciencemag.org/content/4/123/123pc3">podcast</a> it mentions.</p>
<section id="sickle-cell-disease" class="level2">
<h2 class="anchored" data-anchor-id="sickle-cell-disease">Sickle Cell Disease</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 65.0%;justify-content: center;">
<p>Sickle cell disease affects more than 13 million people worldwide and is responsible for $1.1 billion in costs per year in the United States. A mutation in the hemoglobin molecule causes red blood cells to change shape and stiffen when releasing oxygen. This shape change in many red blood cells can occlude a blood vessel, resulting in a crisis. While this fundamental component of the disease is known, there are many factors and processes relating to this event that are still unknown, resulting in an inability to discern the severity of sickle cell disease for a particular patient, besides the fact that they have it. The ability to predict the severity of the sickle cell disease would both aid the development of new therapies and guide clinical intervention.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 35.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/characterize-sickle-cell/Sickle_cell.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Red blood cells with abnormal Hemoglobin (HbS) can form into a sickle shape and occlude blood vessels (image&nbsp;<a href="https://www.nhlbi.nih.gov/health/sickle-cell-disease">source</a>)</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="characterizing-disease-severity" class="level2">
<h2 class="anchored" data-anchor-id="characterizing-disease-severity">Characterizing Disease Severity</h2>
<p>The authors of this paper have previously demonstrated that they could simulate the vaso-occlusive crisis events by altering the oxygen concentration of sickle cell disease blood flowing through a capillary-sized microchannel. This paper takes it a step further and quantifies how the blood conductance, defined as velocity per unit pressure drop, changes during the events and uses it as a measure of disease severity. When the authors reduced the oxygen content, blood velocity would decrease, despite the constant pressure applied. The authors hypothesized that the conductance would change faster for patients with severe sickle cell disease as opposed to patients with a more benign form of the disease. You can see that the conductance of a patient with benign sickle cell disease (A) and that of a patient with severe sickle cell disease (B) are drastically different.</p>
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/characterize-sickle-cell/Comparing_blood_conductance.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Blood from a patient with benign sickle cell disease (A) and sever sickle cell disease (B) were both subjected to changes in oxygen concentration, indicated by the top panels. This resulted in drastically different changes in conductance, which could distinguish the two types of patients.</figcaption>
</figure>
</div>
</section>
<section id="device-value" class="level2">
<h2 class="anchored" data-anchor-id="device-value">Device Value</h2>
<p>As I mentioned, this device has potential use in developing therapies for sickle cell disease. The authors demonstrated this with 5-hydroxymethyl furfural (5HMF), which is known to increase hemoglobin oxygen affinity. Hemoglobin with a higher oxygen affinity would retain its ‘safe’ structure as it would release its oxygen less readily. As expected, this molecule caused a fivefold slower reduction in conductance change compared to an untreated, severe blood sample. While this device’s strength originates in its focus on biophysical markers, it could also be utilized to further understand the process of vaso-occlusive events and guide the handling of patients and discovery of effective therapies.</p>
<p>Regardless of the praise this paper has already received, I think it’s rather solid, and I’m not sure what else I would have liked to see addressed. Don’t expect to see this in your local pharmacy any time soon, though, since it can’t predict the occurrence of crises, but instead would indicate what treatment a patient would need.</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Wood DK, Soriano A, Mahadevan L, Higgins JM, &amp; Bhatia SN (2012). A Biophysical Indicator of Vaso-occlusive Risk in Sickle Cell Disease <span style="font-style: italic;">Science Translational Medicine, 4</span> (123), 1-8 PMID: <a href="http://www.ncbi.nlm.nih.gov/pubmed/22378926">22378926</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Lab on a Chip</category>
  <category>Hematology</category>
  <category>MIT</category>
  <category>Harvard</category>
  <category>Diagnostics</category>
  <guid>https://www.microfluidicfuture.com/blog/characterize-sickle-cell/index.html</guid>
  <pubDate>Mon, 09 Apr 2012 00:00:00 GMT</pubDate>
  <media:content url="https://www.microfluidicfuture.com/blog/characterize-sickle-cell/Sickle_cell.jpg" medium="image" type="image/jpeg"/>
</item>
<item>
  <title>Getting to the Root of Microfluidics</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/getting-to-the-root-of-microfluidics/index.html</link>
  <description><![CDATA[ 




<p>It’s not hard to see that a lot here at Microfluidic Future focuses on the medical applications of microfluidics, but that doesn’t mean that I’m not interested in other ways the technology can be used. I love to see novel applications of microfluidics because progress for anyone is progress for everyone. That brings me to today’s post on the RootChip. If the name isn’t a total give away, I recently came across an article that uses a microfluidic chip to study the roots of plants. In the article, “The RootChip: An Integrated Microfluidic Chip for Plant Science” by Stephen Quake and other researchers from Stanford University, a device is developed to study the roots of <em>Arabidopsis thaliana</em>.</p>
<section id="studying-arabidopsis-thaliana-roots" class="level2">
<h2 class="anchored" data-anchor-id="studying-arabidopsis-thaliana-roots">Studying <em>Arabidopsis Thaliana</em> Roots</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-panel quarto-layout-cell" style="flex-basis: 65.0%;justify-content: center;">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p><em>Arabidopsis thaliana</em> has been extensively studied and is akin to the drosophila or zebrafish. It’s not easy to study the roots of a plant because they are sensitive to dehydration and physical damage, which could occur with mounting. Ideally they would be observed as close to <em>in vivo</em> as possible. The authors set out to study the <em>Arabidopsis</em> roots in parallel perfusion chambers, allowing many seedlings to be studied at once. To prove their concept, they used roots “expressing a genetically encoded fluorescence sensor for Glc and Gal.” This would allow them to non-invasively detect the Glc and Gal metabolite levels in real time.</p>
</div>
</div>
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Before introduction to the RootChip, <em>Arabidopsis</em> seeds are germinated in agar medium filled micropipette tips. This germination prior to attachment to the RootChip allows the roots to be screened for adequate growth and desired properties. After 5 days of germination, the tips are mounted on the RootChip. The roots continue to grow into the RootChip’s observation chambers which are filled with liquid medium. The microfluidic channel that leads from the inserted tip transitions from vertical to horizontal and the root typically aligns with the direction of flow. The entire RootChip is encased in a chip carrier that includes water reservoirs to ensure that proper humidity is maintained throughout the study.</p>
</div>
</div>
</div>
<div class="quarto-layout-cell" style="flex-basis: 35.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/getting-to-the-root-of-microfluidics/rootchip_figure1.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">The current RootChip handles 8 seedlings with independent control. After previous germination, tips containing the seedlings are inserted. The roots can readily be analyzed and observed in the flow chamber.</figcaption>
</figure>
</div>
</div>
</div>
</div>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 65.0%;justify-content: center;">
<p>The roots were subjected to pulses of medium spiked with either Glc or Gal. Geneticaly encoded fluorescence sensors allowed for cytosolic Glc and Gal measurements, and the authors recorded reproducible elevations in the roots’ corresponding sugar concentrations. Gal is a well-known root growth inhibitor and the authors examined its effect while perfusing the roots with Gal for a long period of time. They observed darkening of the tissue and a loss of normal cytosolic signal distribution, indicating cell death and tissue alterations due to the long Gal exposure. The authors also noticed swelling epidermal cells, which would indicate a defect in the integrity of the cell wall.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 35.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/getting-to-the-root-of-microfluidics/RootChip_schematic.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Each seedling in the RootChip feeds into its own flow chamber. The entire RootChip can be mounted on a microscope and is enclosed to maintain humidity.</figcaption>
</figure>
</div>
</div>
</div>
</div>
<p>The authors demonstrated the RootChip’s use to observe developing roots in parallel. Their method allows for different properties of the roots to be studied at once with live imaging. Further, the chip’s total control over the perfusion environment allows for complicated experiments. The authors also claim:</p>
<p>“The RootChip will greatly facilitate the ability to investigate nutrient uptake in different root zones, cell type-dependent metabolite flux, and the response of individual cells (such as root hair cells) to different environmental stimuli.”</p>
</section>
<section id="value-of-rootchip-design" class="level2">
<h2 class="anchored" data-anchor-id="value-of-rootchip-design">Value of RootChip Design</h2>
<p>I don’t have any experience in plant study, but this device seems very promising, and I’m excited to see what it leads to in both plant and biomedical microfluidic research. While the use of Gal and Glc may be exciting to some, it is really irrelevant and could be replaced by any other fluorescent markers. Let’s look instead at the capabilities that the RootChip demonstrated. First, the chip allowed the researchers to process 8 seedlings in parallel, which is always a timesaver! The authors noted that in its current configuration, 8 seedlings could be used, but modifications to the design could enable them to use more than 30 seedlings. The design also saves time since the seeds can begin germination externally before introduction to the chip. This allows researchers to select ‘high-achieving’ seedlings, and they won’t have wasted space on a dud.</p>
<p>Moving onto the experiment-enabling design of the chip, we can see that each perfusion chamber is independent and gives the user total control over several simultaneous experiments. This by itself is fine: You could use the RootChip to control your experiments and then use some other means to analyze the results. But with bright-field microscopy, the roots can be observed during and after the experiment in their ‘natural’ environment. I said before that I’m not an expert on plants, so I really don’t know the extent to which roots can be at least partially transparent. The transparency of the root and the bright-field microscopy allowed them to track the fluorescently-labeled metabolite activity, the swelling of the cells and the darkening of the root from death. What else could you observe about a root in the RootChip? And what else besides a root could you observe in the perfusion chamber? I guess you could look at some parasites like a tapeworm and watch them grow and respond to environmental changes. But would you really want to? I have a 100 yard rule about how close I let tapeworms get to my insides.</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Grossmann, G., Guo, W., Ehrhardt, D., Frommer, W., Sit, R., Quake, S., &amp; Meier, M. (2011). The RootChip: An Integrated Microfluidic Chip for Plant Science THE PLANT CELL ONLINE, 23 (12), 4234-4240 DOI: <a href="http://dx.doi.org/10.1105/tpc.111.092577">10.1105/tpc.111.092577</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Lab on a Chip</category>
  <category>Stephen Quake</category>
  <category>Stanford University</category>
  <guid>https://www.microfluidicfuture.com/blog/getting-to-the-root-of-microfluidics/index.html</guid>
  <pubDate>Wed, 07 Mar 2012 00:00:00 GMT</pubDate>
</item>
<item>
  <title>A Case for Oral Diagnostics with Microfluidics</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/oral-diagnostics/index.html</link>
  <description><![CDATA[ 




<section id="whats-so-great-about-oral-diagnostics" class="level2">
<h2 class="anchored" data-anchor-id="whats-so-great-about-oral-diagnostics">What’s So Great About Oral Diagnostics?</h2>
<p>Well, a lot of things, but let’s start with the basics. In order to use a microfluidic device, you need some type of fluid right? Sure if you had some powder or fine material you could suspend it in a fluid, but for simplicity sake, let’s look at fluids as our test material. If you wanted to run a health-related diagnostic, you only have so many bodily fluids available before you have to get creative and very invasive:</p>
<ul>
<li>Blood</li>
<li>Urine</li>
<li>Saliva</li>
<li>Sweat</li>
<li>Mucus</li>
<li>Tears</li>
</ul>
<p>Out of all those fluids, blood (or serum) has been the preferred liquid. It is extremely rich in information and can expose a lot about a systemic condition or report on ailments located deep within the body. You have to filter it if you don’t want the blood cells in your sample, but it’s just a needle prick away. Other ‘fluids’ like mucus or saliva require a bit more work because of how thick and viscous they are, plus you need to filter out the debris floating around in your mouth. If blood is so great, why do we need anything else? Although blood is a great global fluid, sometimes you can get more detailed information by going closer to the source of the problem and choosing a more local fluid, but perhaps one of the greatest reasons is because the process to obtain the blood is still invasive. In the ideal microfluidics world of the future, we would need very small sample sizes and pin pricks wouldn’t be that bad. For now, spitting into a cup is still easier than and more enjoyable than getting stuck. Plus, exposed blood is always a health concern, and should definitely be avoided if possible.</p>
<p>Okay, so I guess you can see why you might want to investigate other fluids, but why saliva? Like I said before, there are some analytes from the blood present in saliva in lower concentrations, like <a href="http://en.wikipedia.org/wiki/C-reactive_protein">C-Reactive Protein</a> (CRP). In fact, tests have been proposed to monitor growth factors, drugs of abuse, steroids and infectious diseases using oral fluid. CRP is a possible indication of inflammation and is released in events like heart attacks. Detection of this protein along with others can be a good indication of an acute myocardial infarction, but you wouldn’t be able to use that alone. CRP may be present for other types of inflammation, especially a local one occurring in the mouth.</p>
</section>
<section id="tackling-periodontal-disease-early" class="level2">
<h2 class="anchored" data-anchor-id="tackling-periodontal-disease-early">Tackling Periodontal Disease Early</h2>
<p>But let’s not focus solely on detecting global diseases and problems. It’s still valuable to detect diseases in the mouth. Periodontal disease is a common oral infectious disease that is a leading cause of tooth loss in adults. Currently, clinical practices don’t have the capability to detect the onset of inflammation leading to periodontal disease and can’t identify the patients at the greatest risk for disease progression. A Point-of-Care device to detect this onset would permit earlier detection and could be utilized outside of the dentist’s office. Testing for periodontal disease can become much easier and widespread since you don’t need a highly trained professional to run the test, and it can be done in health care clinics or at home. There are many underserved communities that cannot afford to visit the dentist, but cheap, regular screening for disease can allow them to manage a disease before it gets out of hand. Additionally, preventing oral diseases can go a long way for the rest of the body, as periodontal disease has been connected to cardiovascular disease, stroke and osteoporosis.</p>
</section>
<section id="engaging-saliva-in-pharmacogenomics" class="level2">
<h2 class="anchored" data-anchor-id="engaging-saliva-in-pharmacogenomics">Engaging Saliva in Pharmacogenomics</h2>
<p>Finally, oral fluids can play a part in pharmacogenomics studies. Pharmacogenomics is the marriage of genetics and pharmacology. While we may think that we understand the processes of diseases, the diseases and their treatments can vary greatly from person to person depending on genetics. In an ideal world, every single drug and treatment we receive would be tailored specifically to our DNA. There is still a lot of work needed to find out which genes have greater effects on both the disease and treatment, but in order to learn more and to eventually provide tailored treatments, we need to understand our own DNA. Oral fluid can be a great source to obtain that DNA. The DNA we use can come from anywhere, so why not easily dislodge some cells in the mouth instead of pricking ourselves with needles?</p>
<p>There are many bodily fluids for us to choose from, but saliva has some key advantages. There are both important local and global diseases it can test. It certainly is less invasive than blood and does not require the same privacy (and planning) as urine collection. But there still needs to be work to determine the ideal biomarkers in the saliva and amplify their signals. There’s some good advice found in “Translational and Clinical Applications of Salivary Diagnostics” that not only applies to saliva POC devices, but to all their POC device brethren:</p>
<p>“While their analysis core is substantially smaller than that of benchtop alternatives, the network of macroscopic laboratory-based infrastructure required for sample processing, analyte detection, data processing, and reagent handling implies that these platforms are best described as ‘chips-in-a-lab’ rather than true ‘labs-on-a-chip’.”</p>
<p>No matter what fluid we’re using, or disease we’re screening, we need to design these devices with the clear motivation for them to be used outside our labs, and in the wild.</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-panel quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Giannobile, W., McDevitt, J., Niedbala, R., &amp; Malamud, D. (2011). Translational and Clinical Applications of Salivary Diagnostics <span style="font-style: italic;">Advances in Dental Research, 23</span> (4), 375-380 DOI: <a href="http://dx.doi.org/10.1177/0022034511420434">10.1177/0022034511420434</a></p>
</div>
</div>
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Hart, R., Mauk, M., Liu, C., Qiu, X., Thompson, J., Chen, D., Malamud, D., Abrams, W., &amp; Bau, H. (2011). Point-of-care oral-based diagnostics <span style="font-style: italic;">Oral Diseases, 17</span> (8), 745-752 DOI: <a href="http://dx.doi.org/10.1111/j.1601-0825.2011.01808.x">10.1111/j.1601-0825.2011.01808.x</a></p>
</div>
</div>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Rice University</category>
  <category>John T McDevitt</category>
  <category>Point of Care</category>
  <category>Oral Fluids</category>
  <category>Periodontal Disease</category>
  <category>Pharmacogenomics</category>
  <guid>https://www.microfluidicfuture.com/blog/oral-diagnostics/index.html</guid>
  <pubDate>Wed, 01 Feb 2012 00:00:00 GMT</pubDate>
</item>
<item>
  <title>Spin Silk Like a Spider! No Legs Required (Just Microfluidics)</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/spider-silk-biomimetics/index.html</link>
  <description><![CDATA[ 




<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-figure quarto-figure-center" style="flex-basis: 10.7%;justify-content: center;">
<figure class="figure">
<p><a href="http://researchblogging.org/news/?p=2936"><img src="https://www.microfluidicfuture.com/images/rb_editors-selection.png" class="img-fluid figure-img"></a></p>
</figure>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p><em>Author’s note: This post was chosen as an Editor’s Selection at <a href="http://researchblogging.org/news/?p=2936">ResearchBlogging.org</a>. Thanks for the support!</em></p>
</div>
</div>
</div>
<section id="biomimetics" class="level2">
<h2 class="anchored" data-anchor-id="biomimetics">Biomimetics</h2>
<p>Biomimetics. I love that word. Well, probably not as much as microfluidics, but it’s a close second. If you’re unfamiliar with the word, it basically refers to design that mimics biology. Biological systems have evolved into finely tuned machines, why not mimic them in order to synthesize what we need? Biomimetics isn’t new, it’s been around in one form or another for a long time (my favorite instance is Velcro), but our capabilities are broadening as we are able to manufacture at smaller, micro and nano levels. If you want to learn more about this topic, you should check out the <a href="http://wyss.harvard.edu/viewpage/100/biomimetic-microsystems">Biomimetic Microsystems Platform at the Wyss Institute</a>. Today I’d like to share biomimetic microfluidic research that mimics the silk-spinning process of spiders from Korea University.</p>
</section>
<section id="mimicking-spider-silk" class="level2">
<h2 class="anchored" data-anchor-id="mimicking-spider-silk">Mimicking Spider Silk</h2>
<p><a href="http://biomems.korea.ac.kr/people/page1.asp">Sang-Hoon Lee</a> et al.’s paper “<a href="http://www.nature.com/nmat/journal/v10/n11/full/nmat3108.html">Digitally tunable physiochemical coding of material composition and topography in continuous microfibers</a>” showcases the process of finely tuned silk-spinning and its benefits in Nature Materials. There has been interest in using microfibers as a scaffold in tissue engineering, but there has been little success in achieving microfibers with varying chemical and morphological properties. The researchers have developed a process to continuously spin microfibers while varying their properties spatiotemporally. With a digitally controlled microfluidic chip, they are able to produce microfibers with varying chemical compositions, structures, gas bubble size and type, live cells and morphologies. The inspiration for this project comes from spiders. They can produce seven different types of silk that originate from different glands within the spider. As the need for one type of silk arises, fluid from that specific gland is used and the produced silk’s composition changes.</p>
<p>Lee’s spider-chip has several pneumatically controlled inlets that meet at a central point. The resulting flow is focused by a coaxial, sheath flow. In this case, the researchers chose to create alginate microfibers, although other materials such as chitosan and polyethylene glycol can be used. Since alginate requires Ca­<sup>+</sup> to gel, the sheath contains CaCl<del>2</del> to convert the stream into a fiber. In addition to focusing the resulting stream, the sheath also acts as a lubricant during the gelation process. Multiple microfibers can be produced continuously in at once and twisted together, which allows for parallel and serial encryption. This encoding could be used in biosensing, high-throughput screening and cell positioning for tissue engineering, but the researchers also wanted to tackle specific structures produced by spiders.</p>
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/spider-silk-biomimetics/Silk_Spinning.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Silk spun by spiders can be mimicked by a microfluidic chip combining different streams. The streams used encode the microfibers in series or parallel when twisted with other microfibers.</figcaption>
</figure>
</div>
</section>
<section id="water-collecting-microfibers" class="level2">
<h2 class="anchored" data-anchor-id="water-collecting-microfibers">Water-Collecting Microfibers</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 60.0%;justify-content: center;">
<p>Have you ever seen a spider web in the morning, laden with dew and wondered why the drops of water are spaced out instead of drenching the whole strand? Apparently there are puffs along the silk that attract the water along the silk. These puffs were mimicked by the spider-chip by alternating two different streams, one of which contained the salt CaCl<del>2</del>. After the salt was leached from the structures, they had a higher surface energy than the rest of the microfiber, drawing in the water. The amount of water collected is dependent on the size of the puff, which is tunable and the researchers suggest that this approach could be used in water collection and purification.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 40.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/spider-silk-biomimetics/Water_droplets.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">By leaching salt originally included in the fibers, structures are created that attract the water on the microfibers</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="lending-a-helping-hand-to-neurons" class="level2">
<h2 class="anchored" data-anchor-id="lending-a-helping-hand-to-neurons">Lending a Helping Hand to Neurons</h2>
<p>Spider eggs are encapsulated with grooved silk, which was also reproduced in the spider-card with grooved channels. When embryonic neurons were placed on the grooved silk, their axons and dendrites ended up more aligned than those found on smooth microfibers. This might be a vital component in tissue regeneration after spinal cord or nerve damage. The researchers also demonstrated their ability to encapsulate gas bubbles within the fibers at different frequencies and bubble sizes. Gas bubbles within the microfiber might provide a temporary source of oxygen for cells encapsulated cells within the microfiber. Finally, Lee et al.&nbsp;encapsulated fibroblasts and hepatocytes and measured their viability. Unfortunately they only investigated cell viability for 5 days, which isn’t long enough to determine its practicality. They also encoded a microfiber with a chemoattractant and put it in a cell culture. The migration of cells toward the chemoattractant is evident, showing that a spatially encoded fiber could be useful in cell culture organization.</p>
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/spider-silk-biomimetics/Grooved_Channels.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Grooved channels produce microfibers similar to the grooved silk that encapsulates spider eggs. The grooves enhance alignment of neuron dendrites and axons.</figcaption>
</figure>
</div>
<p>Expanding greatly on the current uses for microfibers, this advancement will hopefully push the use of microfibers forward. The ability to fine tune the properties of segments within a microfiber has its obvious benefits. But this process is also capable of rapid changes in the microfiber in real time. I’m not sure we have the same needs to quickly change the type of silk produced like a spider. But, I wonder what type of system would need to quickly respond to its environment with different microfiber properties. Any ideas?</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Kang, E., Jeong, G., Choi, Y., Lee, K., Khademhosseini, A., &amp; Lee, S. (2011). Digitally tunable physicochemical coding of material composition and topography in continuous microfibres Nature Materials, 10 (11), 877-883 DOI: <a href="http://dx.doi.org/10.1038/nmat3108">10.1038/nmat3108</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Tissue Engineering</category>
  <category>Nature</category>
  <category>Biomimetics</category>
  <guid>https://www.microfluidicfuture.com/blog/spider-silk-biomimetics/index.html</guid>
  <pubDate>Wed, 25 Jan 2012 00:00:00 GMT</pubDate>
  <media:content url="https://www.microfluidicfuture.com/blog/spider-silk-biomimetics/Silk_Spinning.jpg" medium="image" type="image/jpeg"/>
</item>
<item>
  <title>You Eat Corn? I Make Microfluidics with It</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/corn-microfluidics/index.html</link>
  <description><![CDATA[ 




<section id="recasting-renewable-resources" class="level2">
<h2 class="anchored" data-anchor-id="recasting-renewable-resources">Recasting Renewable Resources</h2>
<p>Some of us are on the search for new renewable materials that can make our lifestyle a bit more sustainable. Although a new resource may be renewable, that doesn’t mean it makes sense to use. For example, many people went crazy over corn-based ethanol because it would eliminate (or at least reduce) America’s dependence on foreign oil. America is the world’s largest producer of corn, but that’s for a reason; we use it for a lot of things already. By diverting a percentage of corn production towards ethanol, we shook up our corn economy, and not necessarily for the better. Yet we find ourselves looking to corn again, but this time as an alternate material for microfluidics. <a href="http://nanobionics.mntl.illinois.edu/LNBL2/home.html">Gang Logan Liu et al.</a> have presented us with a new method for corn-based microfabrication in <a href="http://pubs.rsc.org/en/content/articlelanding/2011/lc/c1lc20726a">“Green microfluidic devices made of corn proteins”</a>. The group from the University of Illinois Urbana-Champagne uses the protein zein, which is actually a byproduct of ethanol production. An existing product previously treated as waste now has the promise of new value; this is exactly what we’re looking for as a green resource.</p>
<p>Not only would this corn-based device be renewable, its disposal would also be more environmentally friendly. The authors stress that this is important in sectors that perform a high number of tests. This could be particularly important for agriculture, which needs to constantly test for pollutants and diseases (it would also give a nice ‘full circle’ type feeling). I’m normally more interested in medical applications for microfluidics, but there are a ton of areas that run chemical tests that can be optimized.</p>
</section>
<section id="zein-film-creation" class="level2">
<h2 class="anchored" data-anchor-id="zein-film-creation">Zein Film Creation</h2>
<p>This is not the first time Zein has been examined as a viable resource; it has been studied for use in coatings, adhesives, food packaging, drug and functional food delivery systems. Zein is a good candidate for microfluidics because it resembles a rod, and self-organizes with other rods into a two-dimensional film. The authors employed a soft lithography fabrication process using PDMS as a master. Once a single layer was molded, the authors examined binding processes with glass slides as well as other zein layers. While it is conceivable that someone would want to use a glass-zein or zein-zein device, it is also necessary to test it with glass because zein is opaque and prevents us from visually evaluating how well it functions.</p>
</section>
<section id="zein-film-attachment" class="level2">
<h2 class="anchored" data-anchor-id="zein-film-attachment">Zein Film Attachment</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 55.0%;justify-content: center;">
<p>Two methods for attachment were considered: solvent and vapor deposition. Both methods involve heating the surfaces and coating with ethanol before mating the sides. In solvent deposition, the zein side is placed on an ethanol-coated surface to pick up a thin layer before sealing. In vapor deposition, the zein side is exposed to ethanol vapor before sealing. The process of heating and exposing to ethanol allows the zein to become more mobile as well as crosslink with either the opposing zein surface or the micro voids in the glass.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 45.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/corn-microfluidics/Corn_Zein_Microfabrication.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Zein film is prepared via soft lithography, using PDMS as a master. It is sealed to another surface by applying it to ethanol solvent or vapor.</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="zein-microfabrication-results" class="level2">
<h2 class="anchored" data-anchor-id="zein-microfabrication-results">Zein Microfabrication Results</h2>
<p>The authors tested the zein-structures in a couple different ways, but they basically boiled down to how well the channels were replicated, sealed and able to allow for normal microfluidics operations. The resulting channels deviated slightly from the master, which could be rectified by reducing the elasticity of the PDMS or changing the zein film thickness. When comparing the solvent and vapor depositions, reliable results were obtained using the vapor. When the solvent was deposited, evidently extra ethanol was transferred to the zein film, distorting the geometry of the channels. While the authors demonstrated that zein sealed well, they did note that it is a somewhat permeable material, and this could be manipulated in some controlled way. Also of note is the fact that zein autofluoresces. Zein is excited using wavelengths from 450 to 490 nm, resulting in excitation emissions at 550 nm to 580 nm. While this doesn’t line up with the properties of Green Fluorescent Protein, it might align with others, making fluorescent detection a bit harder.</p>
<p>I think that the use of zein is promising. It utilizes a renewable material in a new way that gives value to a pre-existing process. Not only is zein renewable, but it is biodegradable, which will answer one of the problems that will surely arise when microfluidic devices have worked their way into mass production. I think we’ll have to see what complicated structures can be created with zein and what solvents really shouldn’t be used.</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Luecha, J., Hsiao, A., Brodsky, S., Liu, G., &amp; Kokini, J. (2011). Green microfluidic devices made of corn proteins Lab on a Chip, 11 (20) DOI: <a href="http://dx.doi.org/10.1039/C1LC20726A">10.1039/C1LC20726A</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Materials</category>
  <category>Lab on a Chip</category>
  <category>RSC Lab on a Chip</category>
  <guid>https://www.microfluidicfuture.com/blog/corn-microfluidics/index.html</guid>
  <pubDate>Tue, 06 Dec 2011 00:00:00 GMT</pubDate>
  <media:content url="https://www.microfluidicfuture.com/blog/corn-microfluidics/Corn_Zein_Microfabrication.jpg" medium="image" type="image/jpeg"/>
</item>
<item>
  <title>Microfluidics… In Space?</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/microfluidics-space/index.html</link>
  <description><![CDATA[ 




<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-panel quarto-layout-cell" style="flex-basis: 65.0%;justify-content: center;">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>What realm of life is safe from microfluidics? Hopefully none, as the technology continues to work its way into our lives. Although few us can say we have been to space, but those astronauts (or cosmonauts) up there now can look forward to a bit more microscale flow in the world.</p>
</div>
</div>
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>I recently came across an <a href="http://www.popsci.com/technology/article/2011-11/check-astronaut-health-esa-developing-lab-chip-works-space">article at Popular Science</a> (which just happens to be one of my favorite websites) about the European Space Agency (ESA), which is planning on deploying microfluidics-based diagnostics into space. The ESA is working with an Irish company <a href="http://www.radisens.com/">Radisens Diagnostics</a> that will produce the device capable of diagnosing ailments in low gravity. The device will require a drop of blood and will test for “blood sugar, liver and kidney function, and more.” Apparently the company already has a similar device and will make some adjustments to make it space-ready. Like the best things that work in space, the device spins, which likely helps the flow in low gravity. The device is about the size of a matchbox, which must make ESA happy, as space and weight are tightly spent when planning trips to space. This lab-on-a-chip will keep the astronauts safer, as they often have to diagnose and treat themselves while in space. Out of anyone in the world, I’d say they have the greatest point-of-care needs. I wonder what will come first: My trip to space with microfluidics, or microfluidics finally finding its rightful place in our everyday lives.</p>
</div>
</div>
</div>
<div class="quarto-layout-cell" style="flex-basis: 35.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/microfluidics-space/Radisens_Diagnostic_Space_Microfluidics.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Radisens’ microfluidic chip will allow astronauts to test for “blood sugar, liver and kidney function, and more.” (Image source)</figcaption>
</figure>
</div>
</div>
</div>
</div>



 ]]></description>
  <category>Industry News</category>
  <category>Point of Care</category>
  <category>Lab on a Chip</category>
  <category>Popular Science</category>
  <category>Diagnostics</category>
  <category>Radisens Diagnostics</category>
  <guid>https://www.microfluidicfuture.com/blog/microfluidics-space/index.html</guid>
  <pubDate>Wed, 30 Nov 2011 00:00:00 GMT</pubDate>
</item>
<item>
  <title>Bloodhound Beads Sniffing out Heart Attacks</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/bloodhound-beads-sniffing-out-heart-attacks/index.html</link>
  <description><![CDATA[ 




<p>How would you detect a heart attack? There are some symptoms that might tell you that you are very likely having a heart attack. Although you might feel pain in the chest, shortness of breath or other known physical symptoms, that doesn’t mean you in are actually having one. Conversely, you may not experience these symptoms but an attack is well on its way. In addition to painful symptoms, an electrocardiogram can be used to further indicate if you’re having a heart attack, but it also isn’t always accurate. But what if you could detect a heart attack by monitoring cardiac specific biomarkers in the blood or saliva? Those attempts are well underway.</p>
<p>Detecting anything in bodily fluids is always a good time for our friend microfluidics to enter the scene. Even after the correct biomarker is established, it must be quantified in a quick and demonstrative way. While biomarker levels vary in statistically significant ways during disease, they may still occur at low levels, making detection very hard. <a href="http://tastechip.com/">John T McDevitt et al.</a> fulfill this need in “A disposable bio-nano-chip using agarose beads for high performance immunoassays.” I actually worked in Dr.&nbsp;McDevitt’s lab while I was at Rice University, so I’m pretty familiar with his work, although I didn’t work on this project.</p>
<section id="agarose-beads" class="level2">
<h2 class="anchored" data-anchor-id="agarose-beads">Agarose Beads</h2>
<p>In this paper, Dr.&nbsp;McDevitt develops a system of agarose beads for immunoassays that can be implemented in a microfluidic system and tests it on C-reactive protein (CRP). CRP is a biomarker that is elevated during inflammation or heart attacks, which could make it useful when detecting or confirming a heart attack when used in conjunction with other biomarkers. This process uses a sandwich immunoassay, which we’ve seen before when <a href="../../blog/detecting-ovarian-cancer-with-cell-phone-and-microfluidic-chip/index.html">detecting ovarian cancer</a>. However, in this case, 280 µm agarose beads are used to house the immunoassay process. These beads are very porous, providing a large surface area to volume ratio, which affords many antibody-capturing locations to be stationed on and within the bead. Other beads made of polystyrene would only allow capture antibodies on the surface, and would not be able to detect as much of the biomarker in the same volume.</p>
</section>
<section id="protein-sensing-microarray" class="level2">
<h2 class="anchored" data-anchor-id="protein-sensing-microarray">Protein-sensing Microarray</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 65.0%;justify-content: center;">
<p>While the porosity of the bead allows the detection to be enhanced, the shape of the bead is also important in this immunoassay. This system is comprised of an array of microscale PDMS cups, each containing an agarose bead. The cups are shaped like inverted pyramids and feature a small hole at the bottom that allows for fluid to drain. This setup drives fluid through the beads by convection, as it is the only exit point for the fluid. In its simplest form, the system contains three stacked layers: the middle layer contains the microarray of inverted pyramids, which is surrounded by two PDMS layers containing the microfluidic injection and drainage channels. The middle layer is made of an epoxy, and actually originates from a lithography-produced silicon mold. The silicon mold looks exactly the same as the epoxy, but due to the cost and process to produce the silicon, it doesn’t make sense to use it in each system. Instead, it is used as a mold for PDMS, which itself is used to mold epoxy, giving us a copy of the original silicon. The resulting epoxy layer can be incorporated by irreversible covalent bonding to the PDMS layers.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 35.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/bloodhound-beads-sniffing-out-heart-attacks/Microarray_fabrication.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Microarray fabrication following PDMS mold creation from silicon master</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="crp-detection-with-agarose-beads" class="level2">
<h2 class="anchored" data-anchor-id="crp-detection-with-agarose-beads">CRP Detection with Agarose Beads</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 65.0%;justify-content: center;">
<p>The agarose beads are first incubated with CRP specific capture antibodies, capturing the CRP as it is forced through the agarose beads. Detection antibodies are fluorescently tagged and are pumped through beads, specifically attaching to the anchored CRP. The fluorescence of the beads will correspond to CRP concentration in the sample. In order to calibrate the system properly, control beads are also included in the array which contain antibodies for another antigen. This system is able to produce a precise dose-response curve. Its limit of detection is about 1 ng/ml, which is far below the physiological range of CRP, but may be used while processing saliva, which must be diluted several times since it’s highly viscous. You can also see that the fluorescent green signal infiltrates the bead and is not limited to the surface. This demonstrates the porous agarose bead’s ability to capture more CRP and deliver a stronger signal.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 35.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/bloodhound-beads-sniffing-out-heart-attacks/Agarose_bead_CRP_capture.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">A&nbsp;CRP capture and flagging&nbsp;B&nbsp;CRP detection penetrating bead&nbsp;C&nbsp;CRP/fluorescence dose response curve</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="modelling-the-microarray-with-computational-fluid-dynamics" class="level2">
<h2 class="anchored" data-anchor-id="modelling-the-microarray-with-computational-fluid-dynamics">Modelling the Microarray with Computational Fluid Dynamics</h2>
<p>This system was also simulated using the computational fluid dynamics program COMSOL, and the results were similar to those found in the real world. Interestingly, there are some special considerations to think about when measuring the intensity of the beads. Not all flow through the array is equal. First, there is a bit of a pressure gradient across the beads such that the beads closest to the source experience the greatest pressure and those further away experience slightly lower pressure. The increased pressure causes more CRP and tagged antibodies through the beads resulting in a higher signal. Second, the size of the drain in each pyramid may vary, which would again affect the pressure experienced by each bead and its resulting intensity. Finally, any deviations in the bead shape will alter how it sits in the inverted pyramid. Once again, smaller beads sitting lower in the holes will experience higher pressures and signals.</p>
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/bloodhound-beads-sniffing-out-heart-attacks/Microarray_computational_fluid_dynamics.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Computational Fluid Dynamics simulates fluid flow and antigen capture</figcaption>
</figure>
</div>
</section>
<section id="final-thoughts" class="level2">
<h2 class="anchored" data-anchor-id="final-thoughts">Final Thoughts</h2>
<p>This paper presents the final component in an immunoassay intended for microfluidic chips. While there are many other processes which must be carried out before the biomarker level can be measured, this method can also be used for a range of biomarkers and is only limited by the nature of the fluid and the concentration of the biomarker.</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Du, N., Chou, J., Kulla, E., Floriano, P., Christodoulides, N., &amp; McDevitt, J. (2011). A disposable bio-nano-chip using agarose beads for high performance immunoassays Biosensors and Bioelectronics, 28 (1), 251-256 DOI: <a href="http://dx.doi.org/10.1016/j.bios.2011.07.027">10.1016/j.bios.2011.07.027</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Diagnostics</category>
  <category>Immunoassay</category>
  <category>Rice University</category>
  <category>John T McDevitt</category>
  <category>Point of Care</category>
  <category>Hematology</category>
  <category>Oral Fluids</category>
  <guid>https://www.microfluidicfuture.com/blog/bloodhound-beads-sniffing-out-heart-attacks/index.html</guid>
  <pubDate>Tue, 08 Nov 2011 00:00:00 GMT</pubDate>
  <media:content url="https://www.microfluidicfuture.com/blog/bloodhound-beads-sniffing-out-heart-attacks/Microarray_computational_fluid_dynamics.jpg" medium="image" type="image/jpeg"/>
</item>
<item>
  <title>PDMS: The Favorite Material of Microfluidics (for now)</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/pdms-the-favorite-material-of-microfluidics-for-now/index.html</link>
  <description><![CDATA[ 




<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 70.0%;justify-content: center;">
<p>Whether you’ve been learning about microfluidics here at Microfluidic Future or somewhere else, you’ve undoubtedly come across the elastomer poly(dimethylsiloxane) (PDMS). PDMS has radically changed the capabilities of microfluidics (and its price tag) since it was <a href="http://pubs.acs.org/doi/abs/10.1021/ac980656z">first brought into microfluidics</a> by George Whitesides in 1998. PDMS has effectively replaced glass and silicon which were borrowed from existing micromachining industries. PDMS has great resolution and can contain sub-0.1 µm features. But how is PDMS used, and what makes it so great? Hopefully you’ll have these answers by the end of this post.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 30.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/pdms-the-favorite-material-of-microfluidics-for-now/Microfluidic_channel_in_PDMS.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Precise microfluidic channel in PDMS</figcaption>
</figure>
</div>
</div>
</div>
</div>
<section id="pdms-fabrication" class="level2">
<h2 class="anchored" data-anchor-id="pdms-fabrication">PDMS Fabrication</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-panel quarto-layout-cell" style="flex-basis: 65.0%;justify-content: center;">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Soft lithography is a widely used technique to create PDMS structures. This process first requires a mold, or a master, generally produced by photolithography. The mold must represent the hollow space of the microfluidic chip, where the fluids will eventually flow. PDMS is formed by mixing one component which contains silicon hydride groups and another component which contains a vinyl group. This mixture is then poured on top of the master. PDMS cures to a solid after an hour at 70°C, and can then be peeled away from the master without damage to either part, allowing the master mold to be reused. The earlier steps can be completed within 24 hours, and replicas can be mass produced after designing and creating a master.</p>
</div>
</div>
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>After removing the PDMS replica, we have an open space in the structure from the master, but our channels have no bottom! We next have to seal the PDMS to another surface, such as glass, silicon, or itself. More importantly, PDMS can be sealed reversibly or irreversibly.</p>
</div>
</div>
</div>
<div class="quarto-layout-cell" style="flex-basis: 35.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/pdms-the-favorite-material-of-microfluidics-for-now/PDMS_casting_from_photolithography.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">PDMS fabrication process, beginning with photolithography</figcaption>
</figure>
</div>
</div>
</div>
</div>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-panel quarto-layout-cell" style="flex-basis: 65.0%;justify-content: center;">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Van der Waals forces allow reversible sealing to smooth surfaces. This seal is airtight, but can only withstand pressures around 5 psi. Adhesive silicone or cellophane tapes can also be used to create a reversibly seal that is stronger than PDMS alone. Reversible seals allow for reuse or added functionality. Remember that the PDMS used in the <a href="../../blog/simbas-everything-the-blood-touches-is-our-kingdom/index.html">SIMBAS lab-on-a-chip</a> was sealed reversibly to the glass, allowing reuse or future analysis.</p>
</div>
</div>
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>In some cases, a lab-on-a-chip may require an irreversible seal, especially if operating under higher pressures. PDMS can be irreversibly sealed by exposing it (and possibly the other surface) to oxygen plasma. However, the two pieces of chip must be aligned within a minute or else the oxidized PDMS surface will reconstruct in the air.</p>
</div>
</div>
</div>
<div class="quarto-layout-cell" style="flex-basis: 35.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/pdms-the-favorite-material-of-microfluidics-for-now/PDMS_sandwiching_membrane.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Complex PDMS structure “sandwiching” a membrane between two layers</figcaption>
</figure>
</div>
</div>
</div>
</div>
<p>Complex structures can be created by “sandwiching” multiple layers of PDMS. Furthermore, additional components like membranes can be included in this sandwich. This can be a bit of a challenge depending on the complexity of the features, and micro-stages have been created to ensure perfect alignment after oxidation. Alternatively, PDMS can be sealed with the aid of polar solvents. A thin film of a polar solvent is placed between PDMS layers and then heated, evaporating the solvent and sealing the layers.</p>
<p>Instead of using photolithography to create the mold, 3D printing can also be used. 3D printing prints small globules of material according to a CAD file to make 3D structures. 3D printing itself has been growing in capabilities due to its extremely quick prototyping speed. It can achieve a resolution between 50 and 100 µm, which is suitable for microfluidic devices. This mold would then be used in the same way to create PDMS replicas.</p>
</section>
<section id="microfluidic-components" class="level2">
<h2 class="anchored" data-anchor-id="microfluidic-components">Microfluidic Components</h2>
<p>Microfluidic chips can be very complex, featuring pumps, valves and mixers. These parts can easily be implemented in a PDMS structure. Mixers can be incorporated into the masters, transferring them to the floor of a channel. Other parts that are made separately, like some of the <a href="../../blog/microvalve-traffic-light-microfluidics/index.html">microvalves I discussed previously</a>, can be placed in the PDMS while curing. This allows a single master to be very versatile while moving independent features about the device.</p>
</section>
<section id="key-features" class="level2">
<h2 class="anchored" data-anchor-id="key-features">Key Features</h2>
<p>Here are some key features of PDMS adapted from “<a href="http://pubs.acs.org/doi/abs/10.1021/ar010110q">Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices</a>” by Whitesides.</p>
<table class="table">
<colgroup>
<col style="width: 32%">
<col style="width: 32%">
<col style="width: 32%">
</colgroup>
<tbody>
<tr class="odd">
<td><strong>Property</strong></td>
<td><strong>Characteristic</strong></td>
<td><strong>Consequence</strong></td>
</tr>
<tr class="even">
<td>Optical</td>
<td>transparent; UV cutoff, 240 nm</td>
<td>optical detection from 240 to 1100 nm</td>
</tr>
<tr class="odd">
<td>Electrical</td>
<td><p>insulating; breakdown voltage,</p>
<p>2 x 10<sup>7</sup> V/m</p></td>
<td>allows embedded circuits; intentional breakdown to open connections</td>
</tr>
<tr class="even">
<td>Mechanical</td>
<td><p>elastomeric; tunable Young's modulus, typical value of</p>
<p>~750 kPa</p></td>
<td>conforms to surfaces; allows actuation by reversible deformation; facilitates release from molds</td>
</tr>
<tr class="odd">
<td>Thermal</td>
<td>insulating; thermal conductivity, 0.2 W/(m*K); coefficient of thermal expansion, 310 µm/(m*°C)</td>
<td>can be used to insulate heated solutions; does not allow dissipation of resistive heating from electrophoretic separation</td>
</tr>
<tr class="even">
<td>Interfacial</td>
<td><p>low surface free energy</p>
<p>~20 erg/cm</p></td>
<td>replicas release easily from molds; can be reversibly sealed to materials</td>
</tr>
<tr class="odd">
<td>Permeability</td>
<td>impermeable to liquid water; permeable to gases and nonpolar organic solvents</td>
<td>contains aqueous solutions in channels; allows gas transport through bulk material; incompatible with many organic solvents</td>
</tr>
<tr class="even">
<td>Reactivity</td>
<td>inert; can be oxidized by exposure to plasma</td>
<td>unreactive toward most reagents; surface can be etched; can be modified to be hydrophilic and also reactive toward silanes; etching can alter topography of surfaces</td>
</tr>
<tr class="odd">
<td>Toxicity</td>
<td>nontoxic</td>
<td>can be implanted in vivo; supports mammalian cell growth</td>
</tr>
</tbody>
</table>
<p>Some clear advantages and unique properties can be seen from this table. I would also like to point out some additional advantages and disadvantages.</p>
<section id="advantages" class="level3">
<h3 class="anchored" data-anchor-id="advantages">Advantages</h3>
<ul>
<li>Quicker production time than glass and silicon microfluidic chips</li>
<li>Cheaper than glass and silicon</li>
</ul>
</section>
<section id="disadvantages" class="level3">
<h3 class="anchored" data-anchor-id="disadvantages">Disadvantages</h3>
<ul>
<li>Unless oxidized or treated, the surface of PDMS is hydrophobic which can encourage air bubbles to form in channels and protein adsorption</li>
<li>Elasticity restricts aspect ratio of structures as sagging/shrinking can occur.</li>
</ul>
<p><strong>This is one part of my <a href="../../what-is-microfluidics.html">Microfluidics Beginer’s Guide</a>. Check out the rest of it and keep learning!</strong></p>
</section>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>McDonald, J., &amp; Whitesides, G. (2002). Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices <span style="font-style: italic;">Accounts of Chemical Research, 35</span> (7), 491-499 DOI: <a href="http://dx.doi.org/10.1021/ar010110q">10.1021/ar010110q</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Microfluidics Basics</category>
  <category>Materials</category>
  <category>Harvard</category>
  <category>George M Whitesides</category>
  <guid>https://www.microfluidicfuture.com/blog/pdms-the-favorite-material-of-microfluidics-for-now/index.html</guid>
  <pubDate>Thu, 27 Oct 2011 00:00:00 GMT</pubDate>
</item>
<item>
  <title>Detecting Ovarian Cancer with a Cell Phone and a Microfluidic Chip</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/detecting-ovarian-cancer-with-cell-phone-and-microfluidic-chip/index.html</link>
  <description><![CDATA[ 




<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-figure quarto-figure-center" style="flex-basis: 10.7%;justify-content: center;">
<figure class="figure">
<p><a href="http://researchblogging.org/news/?p=3009"><img src="https://www.microfluidicfuture.com/images/rb_editors-selection.png" class="img-fluid figure-img"></a></p>
</figure>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p><em>Author’s note: This post was chosen as an Editor’s Selection at <a href="http://researchblogging.org/news/?p=3009">ResearchBlogging.org</a>. Thanks for the support!</em></p>
</div>
</div>
</div>
<section id="ovarian-cancer" class="level2">
<h2 class="anchored" data-anchor-id="ovarian-cancer">Ovarian Cancer</h2>
<p>Ovarian cancer is the fifth leading cause of cancer related mortality among women. Like many diseases, there is a stark difference in survival rates depending on detection times. When ovarian cancer is detected at stage I, there is a 90% 5 year survival rate. Compare that with the 33% 5 year survival rate when the ovarian cancer is detected in stage III and IV. This disease is unfortunately asymptomatic at early stages, drastically eliminating the odds of discovery with enough time to make a difference.</p>
<p>While using traditional diagnostics like imaging, biopsy, and genetic analysis is impractical for regular screening, there are alternative methods used for women who are <a href="http://www.cancer.org/Cancer/OvarianCancer/DetailedGuide/ovarian-cancer-risk-factors">high-risk for ovarian cancer</a> or who have family history. Transvaginal sonography can be used annually although it has been shown to have limited efficacy. Blood serum can also be tested to indicate ovarian cancer, but this method only has a sensitivity of 72% at specificity of 95%. Sensitivity and specificity are used to measure how well a system can detect something. To calculate specificity in our case, imagine 100 women without ovarian cancer are tested, and only 5 women are incorrectly told that they have ovarian cancer. This would undoubtedly be corrected in a follow up test. But to calculate sensitivity, imagine 100 women with ovarian cancer and 28 women are incorrectly told that they do not have it.</p>
<p>Not only are these tests inconclusive, they are extremely invasive. In the case of transvaginal sonography, an instrument is inserted in the vagina to check the ovaries. With blood serum testing, blood obviously must be drawn. Biochips currently exist to detect ovarian cancer based on protein biomarkers or DNA sequences, but these rely on fluorescence or chemiluminescence and are designed to be used in laboratory settings. None of the previous methods lend themselves to be used in point-of-care (POC) settings. An ideal POC device would not require expensive parts, be usable by limited trained personnel or be too complex. This would allow it to be used in resource-rich and resource-limited settings, especially if it does not need a continuous power source.</p>
</section>
<section id="detecting-ovarian-cancer-with-urine" class="level2">
<h2 class="anchored" data-anchor-id="detecting-ovarian-cancer-with-urine">Detecting Ovarian Cancer with Urine</h2>
<p>Researchers from Harvard Medical School have developed a cell phone system to detect ovarian cancer that should address the lacking areas of diagnosis so far. “<a href="http://pubs.rsc.org/en/Content/ArticleLanding/2011/LC/C1LC20479C">Integration of cell phone imaging with microchip ELISA to detect ovarian cancer HE4 biomarker in urine at the point-of-care</a>” was featured in the 2011 issue 11 of Lab on a Chip. <a href="http://mit.edu/bammlabs/">Utkan Demirci et al.</a> demonstrate a method to non-invasively detect ovarian cancer efficiently with urine and a cell phone. At the heart of this system is an enzyme-linked immunosorbent assay (ELISA). ELISA is a very common technique used in protein detection. In this case, a sandwich ELISA is used to detect the ovarian cancer biomarker Human epididymis protein 4 (HE4). Antibodies targeted to HE4 are conjugated to horseradish peroxidase which catalyzes a substrate and causes blue color to develop. We should then be able to ascertain the amount of HE4 originally in solution by quantifying the resulting color. This process takes place in three different microfluidic channels on a microchip the size of a stamp. These three channels allow a sample to be treated in triplicate or for many samples to be tested at once.</p>
<div class="columns">
<div class="column" style="width:10%;">
<!-- empty column to create gap -->
</div><div class="column" style="width:80%;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/detecting-ovarian-cancer-with-cell-phone-and-microfluidic-chip/Detecting_Ovarian_Cancer_Urine_ELISA.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">After the urine is loaded in the microfluidic chanel, ELISA is performed resulting in a colorimetric change</figcaption>
</figure>
</div>
</div><div class="column" style="width:10%;">
<!-- empty column to create gap -->
</div>
</div>
</section>
<section id="cell-phone-and-ccd-imaging" class="level2">
<h2 class="anchored" data-anchor-id="cell-phone-and-ccd-imaging">Cell Phone and CCD Imaging</h2>
<p>Two methods were used to detect the change in color. The first method utilized a cell phone (more specifically Sony-Ericsson i790). This took advantage of the built in camera and processing power, allowing all processing steps to be carried out on the single device. The second method uses a lensless charge-coupled device (CCD). CCDs are found in digital cameras and have completely changed the way we capture images. In fact, the cell phone used has its own CCD inside. The CCD is used directly with a computer which analyzes the image with MATLAB. Both methods take a picture of the three microfluidic channels on the chip and compare the colors of the channels to previously measured standards.</p>
<div class="columns">
<div class="column" style="width:10%;">
<!-- empty column to create gap -->
</div><div class="column" style="width:80%;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/detecting-ovarian-cancer-with-cell-phone-and-microfluidic-chip/Detecting_Ovarian_Cancer_Urine_Cell_Phone.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Cell phone takes an image of ELISA results and compares the color to calibrated curves</figcaption>
</figure>
</div>
</div><div class="column" style="width:10%;">
<!-- empty column to create gap -->
</div>
</div>
</section>
<section id="calibration-and-testing" class="level2">
<h2 class="anchored" data-anchor-id="calibration-and-testing">Calibration and Testing</h2>
<p>Before this system can be tested on actual samples, it has to be calibrated with known samples. HE4 was evaluated from 1,250 to 19.5 ng/mL, which was its detection limit. I’m unsure how much urine is actually needed. Each sample was diluted twenty times, and each channel can only handle 96.75 µL including the ELISA solutions. In order to make sure that ELISA was occurring correctly on the microchip, the colored solution was transferred to a 96-well microplate and the optical density was measured with a spectrophotometer. This was validated and a strong correlation between HE4 concentration and color was found for the CCD and cell phone with high R<sup>2</sup> values above 0.90. After this calibration, the system was used to differentiate between the urine samples of 19 women with ovarian cancer and 20 women without ovarian cancer. The standard microplate technique and the cell phone and CCD methods were able to distinguish between the normal and cancer samples with statistical significance. When operating at a specificity of 90%, the cell phone and CCD tests achieved 89.5% and 84.2% sensitivity respectively. These results indicate that the new methods can efficiently and effectively detect ovarian cancer in urine.</p>
</section>
<section id="strengths" class="level2">
<h2 class="anchored" data-anchor-id="strengths">Strengths</h2>
<ul>
<li>Both the CCD and cell phone methods demonstrated their ability to distinguish the difference between healthy and ovarian cancer urine.</li>
<li>These methods are extremely portable and can be used in a POC setting.</li>
<li>No complex machines or techniques are needed, which makes it cost-effective and allows operation by minimally trained personnel.</li>
<li>The low price of these tests makes them more accessible to be used to annually screen high-risk women or to check the efficacy of treatment.</li>
<li>Urine is an attractive diagnostic fluid because it is non-invasive and not intimidating.</li>
<li>It is unclear how well this could work in early detection at stage I of ovarian cancer because the samples used had later stage cancer. It is possible that the current configuration may not be able to differentiate between normal and early stage if HE4 levels vary between stages.</li>
<li>This test could be applied to other diseases with established biomarkers and sandwich ELISAs.</li>
</ul>
</section>
<section id="further-development" class="level2">
<h2 class="anchored" data-anchor-id="further-development">Further Development</h2>
<ul>
<li>It is unclear how well this could work in early detection at stage I of ovarian cancer because the samples used had later stage cancer. It is possible that the current configuration may not be able to differentiate between normal and early stage if HE4 levels vary between stages.</li>
<li>This test could be applied to other diseases with established biomarkers and sandwich ELISAs.</li>
</ul>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Wang, S., Zhao, X., Khimji, I., Akbas, R., Qiu, W., Edwards, D., Cramer, D., Ye, B., &amp; Demirci, U. (2011). Integration of cell phone imaging with microchip ELISA to detect ovarian cancer HE4 biomarker in urine at the point-of-care Lab on a Chip, 11 (20) DOI: <a href="http://dx.doi.org/10.1039/C1LC20479C">10.1039/C1LC20479C</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Cell Phone</category>
  <category>Utkan Demirci</category>
  <category>Immunoassay</category>
  <category>ELISA</category>
  <category>Diagnostics</category>
  <category>Harvard</category>
  <category>Point of Care</category>
  <category>RSC Lab on a Chip</category>
  <category>Urinalysis</category>
  <category>Oncology</category>
  <guid>https://www.microfluidicfuture.com/blog/detecting-ovarian-cancer-with-cell-phone-and-microfluidic-chip/index.html</guid>
  <pubDate>Tue, 18 Oct 2011 00:00:00 GMT</pubDate>
  <media:content url="https://www.microfluidicfuture.com/blog/detecting-ovarian-cancer-with-cell-phone-and-microfluidic-chip/Detecting_Ovarian_Cancer_Urine_Cell_Phone.jpg" medium="image" type="image/jpeg"/>
</item>
<item>
  <title>Clearing Sepsis with Magnetic Microfluidics</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/clearing-sepsis-magnetic-microfluidics/index.html</link>
  <description><![CDATA[ 




<section id="sepsis" class="level2">
<h2 class="anchored" data-anchor-id="sepsis">Sepsis</h2>
<p>Sepsis is a big killer here in the United States. I know that I don’t really think about that in a normal day, but it’s the truth, and we can’t ignore it. As of 2005, it was the 10<sup>th</sup> leading cause of death and was just one of two infectious conditions listed in the leading 15 causes of death. Sepsis develops in 750,000 Americans annually, and more than 210,000 die. (That’s a mortality rate of 28 %!) Sepsis not only kills, but it’s accountable for $16.7 billion in annual economic burden. You can see why we need to focus on sepsis, but what is it exactly? Well, sepsis is a response by our bodies to systemic microbial infections. A range of pathogens can cause this reaction, and there is still no clear answer for all the effects on the body that are attributed to sepsis. In general, sepsis is believed to be caused by an infectious agent that compromises the immune system, leaving it unable to properly clear microbes. Treatments for sepsis have included antibiotics, recombinant drugs, membrane blood filtration and blood transfusions. However, these therapies don’t work effectively enough, and many patients die. Hemofiltration and hemadsorption have also been used to clear the blood, but these techniques can also non-specifically remove blood proteins such as cytokines, which are necessary to fight infectious agents. Whole blood transfusions are able to remove the pathogens, but at the expense of the patient’s own immune components and cells that are needed to keep fighting the infection. With all this stacked against us, what are we to do? Turn to a microfluidic therapy I guess.</p>
<p>If you have read a few posts here at <em>Microfluidic Future</em>, you know I love when microfluidics can be applied in therapy. The technology lends itself well to diagnostics, so any bit of therapeutics always piques my interests. A microfluidics device to combat sepsis has been outlined in “<a href="http://pubs.rsc.org/en/Content/ArticleLanding/2009/LC/b816986a">Micromagnetic-microfluidic blood cleansing device</a>.” <a href="http://wyss.harvard.edu/viewpage/121/donald-e-ingber">Donald Ingber et al.</a> of the Wyss Institute describe a device capable of clearing the fungal pathogen <em>Candida albicans</em> from the blood. This work builds on previous efforts by Ingber and is 1000 times faster. The patient’s bloodstream could be hooked up to the device, which would clear the blood of the targeted pathogens.</p>
</section>
<section id="magnetic-opsonins" class="level2">
<h2 class="anchored" data-anchor-id="magnetic-opsonins">Magnetic Opsonins</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 65.0%;justify-content: center;">
<p>At the heart of this system are magnetic opsonins. These are magnetic micro- or nano-beads that are bound to specific antibodies, in our case, they are anti-<em>C. albicans</em>. This device aims to remove the pathogens from the blood using these opsonins. The authors were able to achieve a binding efficiency of 80% with a bead to pathogen ratio of 120. Although 90% binding occurred between 30 and 60 minutes, about 50% binding was achieved after 5 minutes. The authors believed that a shorter incubation time can be achieved if the device were multiplexed. For example, if each of these devices were longer or attached to each other in series, we could overcome the efficiency of a single device. We could also use multiple devices working simultaneously in parallel, so the entire patient’s blood could be processed faster.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 35.0%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/blog/clearing-sepsis-magnetic-microfluidics/Magnetic_opsonins_bind_to_pathogen.jpg" class="img-fluid"></p>
</div>
</div>
</div>
</section>
<section id="magnetic-microfluidic-cleansing" class="level2">
<h2 class="anchored" data-anchor-id="magnetic-microfluidic-cleansing">Magnetic Microfluidic Cleansing</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 65.0%;justify-content: center;">
<p>The fundamental unit of this device is a set of layered channels that provides an interface between the patient’s blood and a carrier fluid. The two fluids are stacked vertically, with blood on the bottom. A solenoid electromagnet creates a magnetic field which draws the opsonins and their fungal passengers into the carrier fluid. The voltage of the electromagnet was optimized to provide a magnetic field that did not cause an overly strong attraction of the particles, which would have caused them to accumulate on the side of the channel instead of flowing with the carrier fluid.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 35.0%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/blog/clearing-sepsis-magnetic-microfluidics/Clearing_sepsis_with_magnetic_microfluidics.jpg" class="img-fluid"></p>
</div>
</div>
</div>
<p>According to the authors, this lab-on-a-chip performed relatively well in modularity and effectiveness in clearing <em>C. albicans.</em> . This device doesn’t involve much external infrastructure (besides the included electromagnet) and could easily function well in point-of-care therapeutics. To evaluate its performance, the authors attempted to clear <em>C. albicans</em> from 10 mL of human whole blood. The concentration of pathogens in this experiment was 10<sup>6</sup> fungi/mL. The system was able to clear 80% of the pathogen in 30 minutes, which is pretty good. This device may require some heparin to prevent clots within the device, but it would not result in lethal clot formations, hypoperfusion, shock and multiple organ failure seen in current therapies. Additionally, 82% of the opsonins that weren’t bound to the pathogen were cleared as well, which is great because I don’t think that you would want that flowing through your system. This actually leads me to some shortcomings I see in this project, and what I’d like to see in the future.</p>
</section>
<section id="improvements" class="level2">
<h2 class="anchored" data-anchor-id="improvements">Improvements</h2>
<ul>
<li>To start, only 10 mL of blood was processed, and it took 30 min (20mL/h). In a 70 kg male with 4.9 L of blood, it would take about 10 days to process all the blood. But the authors are aware of this, and they’ve proposed additions in serial and in parallel to enhance the clearance efficiency and to do it faster.</li>
<li>During the filtration process, the authors noted that the blood and carrier fluid did not split perfectly at the end of the channels, resulting in 50-60% loss of blood. This is obviously not good for the patient. The carrier fluid in that case was PBS, and the loss was reduced to 13% when the flow of the PBS was increased. With a ratio of flow between the fluids of four, the carrier fluid was able to force the blood to remain in place. But this comes at a cost, because this could imaginably hinder the opsonins’ migration from the blood into the carrier fluid, but the extent of this hindrance has not been quantified by the authors.</li>
</ul>
<div class="columns">
<div class="column" style="width:15%;">
<!-- empty column to create gap -->
</div><div class="column" style="width:70%;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/clearing-sepsis-magnetic-microfluidics/Blood_loss_in_clearing_stream.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Blood loss in carrier stream</figcaption>
</figure>
</div>
</div><div class="column" style="width:15%;">
<!-- empty column to create gap -->
</div>
</div>
<ul>
<li>Although the volume of blood processed can be increased by adding layers to the system, I really don’t know if the authors tackled a clinically relevant level of <em>C. albicans</em> in the blood. I’ve been trying to find out a lethal level of <em>C. albicans</em>, but haven’t been able to find it. This would significantly impact the value of the system and would necessitate further multiplexing to achieve higher pathogen levels.</li>
<li>Finally, I’m not sure how the authors intend to deliver the opsonins to the blood. In this paper, the opsonins were simply incubated in the blood. In the graphics of the device on the cover of Lab on a Chip, the opsonins are introduced to the blood flow shortly before entering the device. This is possible according to the authors if proper multiplexing occurs and binding can be achieved within five minutes. Otherwise, it may be necessary to inject the opsonins into the patient and allow them to incubate before hooking them up to the lab-on-a-chip. But I’m not sure if that is such a good idea.</li>
<li>On a related note, I’m interested in the biocompatibility of the opsonins. The authors demonstrated that they bound rather specifically well to the pathogen, and the red blood cells were left untouched. Although the opsonins are quite small (which <em>could</em> make it worse) they could end up all over the body, giving Magneto even more control over you!</li>
</ul>
<p>I mentioned previously that this paper followed up on previous work done by Ingber, so I think it is safe to say that we’ll be seeing the next iteration in some time. Conceivably, this device could be applied to other pathogens if other opsonins are developed, so this device has a lot of room to grow.</p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-panel quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Melamed, A., &amp; Sorvillo, F. (2009). The burden of sepsis-associated mortality in the United States from 1999 to 2005: an analysis of multiple-cause-of-death data <span style="font-style: italic;">Critical Care, 13</span> (1) DOI: <a href="http://dx.doi.org/10.1186/cc7733">10.1186/cc7733</a></p>
</div>
</div>
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Hotchkiss, R., &amp; Karl, I. (2003). The Pathophysiology and Treatment of Sepsis <span style="font-style: italic;">New England Journal of Medicine, 348</span> (2), 138-150 DOI: <a href="http://dx.doi.org/10.1056/NEJMra021333">10.1056/NEJMra021333</a></p>
</div>
</div>
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Yung, C., Fiering, J., Mueller, A., &amp; Ingber, D. (2009). Micromagnetic–microfluidic blood cleansing device <span style="font-style: italic;">Lab on a Chip, 9</span> (9) DOI: <a href="http://dx.doi.org/10.1039/b816986a">10.1039/b816986a</a></p>
</div>
</div>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Wyss Institute</category>
  <category>Harvard</category>
  <category>Donald Ingber</category>
  <category>Lab on a Chip</category>
  <category>Point of Care</category>
  <category>Therapeutics</category>
  <category>RSC Lab on a Chip</category>
  <category>Hematology</category>
  <guid>https://www.microfluidicfuture.com/blog/clearing-sepsis-magnetic-microfluidics/index.html</guid>
  <pubDate>Wed, 05 Oct 2011 00:00:00 GMT</pubDate>
  <media:content url="https://www.microfluidicfuture.com/blog/clearing-sepsis-magnetic-microfluidics/Magnetic_opsonins_bind_to_pathogen.jpg" medium="image" type="image/jpeg"/>
</item>
<item>
  <title>MicroTAS 2011 Oct 2-6</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/microtas-2011/index.html</link>
  <description><![CDATA[ 




<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 75.0%;justify-content: center;">
<p>Tomorrow is the first day of <a href="http://www.microtas2011.org/">MicroTAS 2011</a> (Oct 2-6), which is taking place in Seattle, WA this year. When I go to bed tonight, I’ll close my eyes and wish really hard, but I’m afraid I won’t open them to find myself magically transported to Rain City. Unfamiliar with MicroTAS? Let’s start with the name; MicroTAS (µTAS, micro-TAS or micro TAS) stands for micro total analysis system. This is simply another self-describing name for a lab-on-a-chip. A micro TAS should be a micro-sized device that contains all necessary steps to perform analysis of a sample. If you’ve read my other posts, this is nothing new, just a different name. Anyway, MicroTAS is a conference held every year on “Miniaturized Systems for Chemistry and Life Sciences.” µTAS is “the premier forum for reporting research results in microfluidics, microfabrication, nanotechnology, integration, materials and surfaces, analysis and synthesis, and detection technologies for life science and chemistry.” The conference is in its 15<sup>th</sup> year and is back in the United States. It takes place every three years in the US and has been in Jeju, South Korea and Groningen, the Netherlands since it was in San Diego in 2008. This year’s conference is chaired by <a href="http://faculty.virginia.edu/landers/Home.html">James Landers</a> of the University of Virginia. His lab focuses on micro TAS topics like integrating functionality, fluidic control, genetic analysis and protein and small molecule analysis.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 25.0%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/blog/microtas-2011/MicroTAS_2011.jpg" class="img-fluid"></p>
</div>
</div>
</div>
<p>Like I said, I won’t be there, but I’ll still point you towards some key components of the conference, and will hopefully be able to give you some updates after the conference. There are a ton of <a href="http://www.microtas2011.org/program.html">different programs at MicroTAS 2011</a>, and I invite you to check them out. This year, the conference will be presenting the following awards:</p>
<ul>
<li><a href="http://www.microtas2011.org/authors/awards/lab.html">Lab on a Chip/Corning Inc.&nbsp;Pioneers in Miniaturization Prize</a></li>
<li><a href="http://www.microtas2011.org/authors/awards/young.html">Analytical Chemistry Young Innovator Award</a></li>
<li><a href="http://www.microtas2011.org/authors/awards/widmer.html">Lab on a Chip Widmer Poster Award</a></li>
<li><a href="http://www.microtas2011.org/authors/awards/cheminas.html">CHEMINAS Poster Award</a></li>
<li><a href="http://www.microtas2011.org/authors/awards/nist.html">NIST/Lab on a Chip Art in Science Award</a></li>
</ul>
<section id="art-in-science-award" class="level2">
<h2 class="anchored" data-anchor-id="art-in-science-award">Art in Science Award</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 65.0%;justify-content: center;">
<p>This is the award I’m most excited about. I think that images of micro-sized structures are really beautiful (with or without artificial colors), and I love to see them get recognition. Last year’s winner of this award was Nicholas Gunn of UC Irvine, and he had his image put on the cover of <a href="https://pubs.rsc.org/en/journals/journalissues/lc#!issueid=lc011006&amp;type=current&amp;issnprint=1473-0197">Lab on a Chip</a>. His image is “a colorized SEM micrograph showing fibroblast cells cultured on microscale pedestals.” The pedestals prevented migration of the fibroblasts while still allowing the exchange of soluble factors. I can’t wait to see this year’s winner, and you can bet that I’ll post it here.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 35.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/microtas-2011/Cell_Block_9_MicroTAS_2010.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Cell Block 9&nbsp;by Nicholas Gunn</figcaption>
</figure>
</div>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Industry News</category>
  <category>RSC Lab on a Chip</category>
  <category>MicroTAS</category>
  <guid>https://www.microfluidicfuture.com/blog/microtas-2011/index.html</guid>
  <pubDate>Sat, 01 Oct 2011 00:00:00 GMT</pubDate>
</item>
<item>
  <title>The Microvalve: The Traffic Light of Microfluidics</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/microvalve-traffic-light-microfluidics/index.html</link>
  <description><![CDATA[ 




<p>You could say that valves in microfluidics (or microvalves) are like traffic lights that control flow along microfluidic channels. But I’d say that they’re more like police barricades, stopping anyone they want, wherever they want. The sole purpose of microvalves is to control flow within a microfluidics device, allowing them to become very complex and more automated. Without microvalves, all reactions and mixing must occur in the same space, unless they were premixed elsewhere, which might just eliminate the advantage of microfluidics.</p>
<p>Every microvalve that has ever existed seems to be covered in “<a href="http://iopscience.iop.org/0960-1317/16/5/R01">A review of microvalves</a>” by <a href="http://small.buffalo.edu/index.html">Kwang W Oh</a> and <a href="http://www.biomems.uc.edu/_main.html">Chong H Ahn</a> from the Journal of Micromechanics and Microengineering. I’ll be covering three of the valves mentioned, but feel free to check out all the other microvalves that didn’t make the cut. A companion paper for this post, “<a href="http://pubs.rsc.org/en/Content/ArticleLanding/2009/LC/b809673b">Incorporation of prefabricated screw, pneumatic, and solenoid valves into microfluidic devices</a>” by <a href="http://gmwgroup.harvard.edu/">George M Whitesides et al.</a> , featured in Lab on a Chip, describes a way to prefabricate these three valves so that they can easily be added to existing lab-on-a-chips.</p>
<section id="solenoid-microvalves" class="level2">
<h2 class="anchored" data-anchor-id="solenoid-microvalves">Solenoid Microvalves</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 75.0%;justify-content: center;">
<p>You guessed it, solenoid microvalves are based on…solenoids! A solenoid is a coil of wire wound in a helix, like a compressed spring. I won’t go into the physics behind it, but a magnetic field is created by passing current through the solenoid. If you put a metallic object within the coil and vary the current, you could move the object. This is the idea behind solenoid microvalves. A solenoid microvalve is simply a solenoid with an actuator inside of it. The actuator is situated above the channel of a microfluidic device and pushes down on the ceiling of the channel to collapse it and obstruct its flow. In this manner, the solenoid microvalve requires an elastomeric lab-on-a-chip, and is rather bulky.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 25.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/microvalve-traffic-light-microfluidics/Prefabricated_Solenoid_Valve.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Prefabricated Solenoid Microvalve</figcaption>
</figure>
</div>
</div>
</div>
</div>
<section id="whitesides-prefab" class="level4">
<h4 class="anchored" data-anchor-id="whitesides-prefab">Whitesides’ Prefab:</h4>
<p>Whitesides’ prefabrication does not involve a dramatic redesign of solenoid microvalves. Instead, he places the same solenoid in PDMS housing, which can accommodate the solenoid’s large footprint.</p>
</section>
</section>
<section id="screw-microvalves" class="level2">
<h2 class="anchored" data-anchor-id="screw-microvalves">Screw Microvalves</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 70.0%;justify-content: center;">
<p>This is another one. You guessed it, microvalves are based on…screws! This is an extremely low tech microvalve that requires little more than a screw. The screw is incorporated into the microfluidic device and deflects the membrane of the channel by twisting it. A ball can be placed beneath the screw to prevent damage to the device. This design is great for lab-on-a-chips that are intended to be disposable or for a low-resource setting. It requires no power, has a small profile (although you need access to screw it manually) and is simple to use. Obviously, it’s not completely automated, but I suppose you could incorporate a small electric screwdriver somewhere.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 30.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/microvalve-traffic-light-microfluidics/Screw_Valve.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Screw Microvalve</figcaption>
</figure>
</div>
</div>
</div>
</div>
<section id="whitesides-prefab-1" class="level4">
<h4 class="anchored" data-anchor-id="whitesides-prefab-1">Whitesides’ Prefab:</h4>
<p>Whitesides’ prefabrication method doesn’t really differ too much from the conventional screw microvalve design. The screw is essentially embedded in a housing which can be joined above an existing microfluidic channel. One of the key advantages argued by Whitesides is that prefabrication regulates the screw microvalves. All the prefabricated screw valves are created in an identical manner, and would require the same degree of rotation to shut off flow. This is important because it may not be possible to see how well the flow is obstructed, resulting in leakage or damage to the channels. Screw valves created by different people at different times may be placed differently. A half-turn of one person’s valve might not properly close the channel, while a half-turn of someone else’s valve might go too far and damage the device.</p>
</section>
</section>
<section id="pneumatic-microvalves" class="level2">
<h2 class="anchored" data-anchor-id="pneumatic-microvalves">Pneumatic Microvalves</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 60.0%;justify-content: center;">
<p>I know it says pneumatic, but these are commonly referred to as Quake Valves, named after <a href="http://thebigone.stanford.edu/index.html">Stephen Quake</a>. Quake valves require additional channels, often perpendicular to the targeted microfluidic channels. The additional channels share a thin, common membrane with the targeted channels. When air at the right pressure is applied through the pneumatic channels, the shared membrane is deflected and obstructs the flow of fluid. This completely changed the field of microfluidics since its <a href="http://pubs.acs.org/doi/abs/10.1021/ac0346407">arrival in 2000, allowing such feats as 400 simultaneous PCR reactions</a>.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 40.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/microvalve-traffic-light-microfluidics/Fluidigm_Quake_Valve.png" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Quake Microvalve (source)</figcaption>
</figure>
</div>
</div>
</div>
</div>
<p>As cool as these microvalves are, they certainly have their drawbacks. First, they require more planning because you not only need to incorporate an additional layer of pneumatic channels, but you also have to route all your channels so that they don’t overlap where you don’t want them to. A small change in the design of your microfluidic device could require a massive redesign. While the solenoid valve certainly has a large footprint over the lab-on-a-chip due to the large size of the solenoid, the Quake valves only require the inclusion of an additional layer, keeping the area directly around the device cleaner. But this setup requires a tank of pressurized gas near the device, so in reality its footprint isn’t so small. This obviously hinders a device from easily leaving the lab. The pneumatic valves can be controlled electronically, allowing a device consisting of multiple independent valves to become more automatic. For instance, Albert Folch of University of Washington created this video of a <a href="http://www.youtube.com/watch?v=eLmecbMmeLM">Microfluidic Ballet</a> by controlling valves according to the frequency of the music by Dimitri Shostakovich.</p>
<section id="whitesides-prefab-2" class="level4">
<h4 class="anchored" data-anchor-id="whitesides-prefab-2">Whitesides Prefab:</h4>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 60.0%;justify-content: center;">
<p>Whitesides’ prefabrication of Quake valves diverges from the most from the conventional out of all three microvalves shown here. Simply consisting of a chamber attached to an air supply placed over a channel, this method doesn’t require any additional layers of valves. A conventional Quake valve would require an entire redesign of the pneumatic channel layer, while a prefabricated Quake valve can simply be relocated over a new channel. When activated, the chamber presses down on the channel wall and obstructs the flow.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 40.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/microvalve-traffic-light-microfluidics/Prefabricated_Quake_Valve_Figure.png" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Prefabricated Quake Microvalve</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
</section>
<section id="final-thoughts" class="level2">
<h2 class="anchored" data-anchor-id="final-thoughts">Final Thoughts</h2>
<p>We’ve only examined three different microvalves here, and you can see how radically unique they are. As we develop new microfluidic applications and materials, we’ll continually develop novel ways to control the flow. A high concentration of valves indicates greater device design sophistication, but even so, less can be more, and our best solution might just be the simplest one.</p>
<p><strong>This is one part of my <a href="../../what-is-microfluidics.html">Microfluidics Beginer’s Guide</a>. Check out the rest of it and keep learning!</strong></p>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-panel quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Oh, K., &amp; Ahn, C. (2006). A review of microvalves <span style="font-style: italic;">Journal of Micromechanics and Microengineering, 16</span> (5) DOI: <a href="http://dx.doi.org/10.1088/0960-1317/16/5/R01">10.1088/0960-1317/16/5/R01</a></p>
</div>
</div>
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 100.0%;justify-content: center;">
<p>Elizabeth Hulme, S., Shevkoplyas, S., &amp; Whitesides, G. (2009). Incorporation of prefabricated screw, pneumatic, and solenoid valves into microfluidic devices <span style="font-style: italic;">Lab on a Chip, 9</span> (1) DOI: <a href="http://dx.doi.org/10.1039/b809673b">10.1039/b809673b</a></p>
</div>
</div>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Lab on a Chip</category>
  <category>Microvalves</category>
  <category>Stephen Quake</category>
  <category>Harvard</category>
  <category>George M Whitesides</category>
  <category>RSC Lab on a Chip</category>
  <category>Microfluidics Basics</category>
  <guid>https://www.microfluidicfuture.com/blog/microvalve-traffic-light-microfluidics/index.html</guid>
  <pubDate>Thu, 29 Sep 2011 00:00:00 GMT</pubDate>
  <media:content url="https://www.microfluidicfuture.com/blog/microvalve-traffic-light-microfluidics/Fluidigm_Quake_Valve.png" medium="image" type="image/png" height="64" width="144"/>
</item>
<item>
  <title>SIMBAS, Everything the Blood Touches Is Our Kingdom</title>
  <dc:creator>Hector </dc:creator>
  <link>https://www.microfluidicfuture.com/blog/simbas-everything-the-blood-touches-is-our-kingdom/index.html</link>
  <description><![CDATA[ 




<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 75.0%;justify-content: center;">
<p>Hey, how’s your biotin? What? No it’s not an organic metal, maybe you call it B7? You’re probably fine, but have you been depressed, lethargic or losing your hair lately? Biotin is pretty important; it’s necessary for metabolism within our cells, so I make sure I never leave home without it. It’s rare for someone to have a biotin deficiency, but if you want to know your levels, give me a drop of your blood, and I’ll have an answer from you in 10 minutes. How? Oh just my self-powered integrated microfluidic blood analysis system (but I like to call it SIMBAS for short).</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 25.0%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/blog/simbas-everything-the-blood-touches-is-our-kingdom/SIMBAS_Lab_on_a_Chip_Cover.jpg" class="img-fluid"></p>
</div>
</div>
</div>
<p>The SIMBAS emerged from Berkeley and was featured on the inside cover of the 2011 Issue 5 of <a href="http://pubs.rsc.org/en/content/articlelanding/2011/lc/c0lc00403k">Lab on a Chip</a>. <a href="http://biopoets.berkeley.edu/">Luke Lee et al.</a> describe a device capable of picomolar detection in “Stand-alone self-powered integrated microfluidic blood analysis system (SIMBAS).” The device can analyze whole blood without a lot of bells and whistles to get in the way. I’m not saying that this doesn’t have a clever design; it just doesn’t have a battery, moving parts or specialized readers. All you need is some blood and a microscope. The device has five independent analysis streams. There are three parts to a stream, the filter, detector and the suction chamber. All of these components are featured in a slab of PDMS sandwiched between two normal glass slides. Before I describe how the features physically work together, it’s important to note the device’s driving force: low pressure. Before use, the SIMBAS is placed in a low-pressure vacuum, degassing it through the single points of entry of each stream, creating a vacuum. When blood is placed at the inlet the vacuum slowly draws it through the system.</p>
<section id="filtration" class="level2">
<h2 class="anchored" data-anchor-id="filtration">Filtration</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 60.0%;justify-content: center;">
<p>After the vacuum sucks in the blood, the red and white blood cells must be filtered out. One major strength of this device is that it receives unadulterated blood. However, in order to prevent the cells from muddling the detection region of the device, they are filtered out by sedimentation. The floor of the 80 µm high, 50 µm wide sample channel opens up to a 2 mm wide, 2 mm deep circular well, which acts as a filter. The large, heavy cells sediment out and take up permanent residence at the bottom depending on the flow rate of the sample. The biomarkers of interest are much lighter and will continue through without joining the blood cells. This produces plasma that is 100% blood cell free, ready for detection. Platelets sediment at lower rates, so they will still remain in the plasma, but this doesn’t seem to be an issue.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 40.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/simbas-everything-the-blood-touches-is-our-kingdom/SIMBAS_lab-on-a-chip_design.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">The degassed chip draws in blood towards the dead-end suction chambers. The wells filter the blood before passing the detection strips.</figcaption>
</figure>
</div>
</div>
</div>
</div>
</section>
<section id="detection" class="level2">
<h2 class="anchored" data-anchor-id="detection">Detection</h2>
<p>Now that the sample has been fully prepared, it is ready for detection. Remember that the PDMS was placed between two glass slides? The authors immobilized streptavidin bars on the underside of the glass roof. This leaves the streptavidin attached to the ceiling, letting it bind with the biotin that flows by. Streptavidin and biotin have one of the strongest known protein-ligand bonds, making it a perfect choice for this device. When tested, blood was spiked with fluorescently-labeled biotin at 1.5 pM. Many other detectors could be immobilized along the same stream or the other four streams. The five parallel streams allow a way to eliminate errors, or test for biomarkers that are not compatible with each other.</p>
</section>
<section id="volume-control" class="level2">
<h2 class="anchored" data-anchor-id="volume-control">Volume Control</h2>
<p>However, we’re still missing the last important feature, the suction trough, an empty region after the detectors. The volume of the trough determines how much sample is drawn through the system. Once the trough is full, flow stops, regardless of how much blood is ready to enter. Modifying the trough volume provides a method to increase the sensitivity of the device. A larger sample volume gives the SIMBAS a better chance to detect a biomarker at low concentrations.</p>
</section>
<section id="final-thoughts" class="level2">
<h2 class="anchored" data-anchor-id="final-thoughts">Final Thoughts</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 60.0%;justify-content: center;">
<p>The current setup only needs 5 µL of whole blood for each stream. To put that into perspective, modern glucometers need 1 µL at most to glucose levels. It is (relatively) a bit more blood, but you wouldn’t be doing this every day. After 10 minutes, biotin at 1.5 pM can be detected by removing the top slide and looking at it under a microscope. That’s a pretty low detection in my book. Crazy low. I’m sitting here trying to think of an accurate needle in a haystack analogy, but it’s not coming. Overall, this is a pretty innovative, yet simple device, and I’ll tell you what I think of its merits and things I’d like to see developed.</p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 40.0%;justify-content: center;">
<div class="quarto-figure quarto-figure-center">
<figure class="figure">
<p><img src="https://www.microfluidicfuture.com/blog/simbas-everything-the-blood-touches-is-our-kingdom/SIMBAS_Biotin_detection.jpg" class="img-fluid figure-img"></p>
<figcaption class="figure-caption">Detection of biotin at 1.5 pM, 150 pM, 15 nM &amp; 1.5 µM</figcaption>
</figure>
</div>
</div>
</div>
</div>
<section id="merits" class="level4">
<h4 class="anchored" data-anchor-id="merits">Merits:</h4>
<ul>
<li>To start, this is has a great design for a point-of-care device, especially in a resource-poor setting. It has no external or moving parts, and requires no power. Sometimes in microfluidics, things can get very complicated with the number of channels, pumps, reagents etc., but this has a very clean and trouble-resistant design. It can be pre-packaged under low pressure so that a user only has to open it to activate the vacuum and use it within a couple of minutes.</li>
<li>The fact that it can receive whole blood also makes it great for point-of-care. Some lab-on-a-chips actually depend on many sample preparation steps or external machines. But all the steps that are needed for it to do its job in isolation should be included, just like SIMBAS. The time between filtration and detection is pretty quick, which is important because the proteins found in the plasma change after longer separations.</li>
<li>This doesn’t require much sample, and is still able to detect biotin at the low concentration of 1.5 pM. I’m not sure how clinically relevant that number is for biotin, but if you can detect that, you can play with the configuration to bring that down (or raise it much more easily).</li>
</ul>
</section>
<section id="what-id-like-to-see" class="level4">
<h4 class="anchored" data-anchor-id="what-id-like-to-see">What I’d like to see:</h4>
<ul>
<li>The authors state that the biotin-streptavidin detection could be replaced by many other couples. I don’t doubt this, but I would like to see what detection levels they could achieve, since biotin-streptavidin has one of the strongest protein-ligand bonds.</li>
<li>In the paper, the authors mention that the detection strips coated on the ceiling were applied on the same day the assay was run. I’d like to know what the shelf life of a prepared card would be, which could really impact their usefulness and value.</li>
<li>As I mentioned previously, the authors detected fluorescent-tagged biotin in the blood, and examined this under a microscope. You can see the captured biotin fluorescing in their figure. But biotin isn’t naturally tagged with a fluorophore, which makes me wonder how they would normally detect a wild biomarker. Perhaps there is a noticeable difference under the microscope; otherwise they will need to introduce some tag in the blood that will act as a secondary binding agent.</li>
<li>The last thing I’d like to see is the microscope. Well, I’d like to see it removed. This microfluidics system would be even greater if it was completely stand-alone. <a href="http://fletchlab.berkeley.edu/">Daniel Fletcher</a> (also from UC Berkeley) has developed a <a href="http://www.plosone.org/article/info%3Adoi%2F10.1371%2Fjournal.pone.0006320">cell phone-powered field microscope</a> capable of fluorescence microscopy, so it isn’t impossible in a resource-poor setting, but it’s just my wishful thinking.</li>
</ul>
</section>
</section>
<section id="references" class="level2">
<h2 class="anchored" data-anchor-id="references">References</h2>
<div class="quarto-layout-panel">
<div class="quarto-layout-row quarto-layout-valign-top">
<div class="quarto-layout-cell" style="flex-basis: 10.7%;justify-content: center;">
<p><img src="https://www.microfluidicfuture.com/images/rb2_large_gray.png" class="img-fluid"></p>
</div>
<div class="quarto-layout-cell" style="flex-basis: 89.3%;justify-content: center;">
<p>Dimov, I., Basabe-Desmonts, L., Garcia-Cordero, J., Ross, B., Ricco, A., &amp; Lee, L. (2011). Stand-alone self-powered integrated microfluidic blood analysis system (SIMBAS) Lab on a Chip, 11 (5) DOI: <a href="http://dx.doi.org/10.1039/C0LC00403K">10.1039/C0LC00403K</a></p>
</div>
</div>
</div>


</section>

 ]]></description>
  <category>Academic Research</category>
  <category>Immunoassay</category>
  <category>Hematology</category>
  <category>Daniel Fletcher</category>
  <category>Luke Lee</category>
  <category>Diagnostics</category>
  <category>UC Berkeley</category>
  <category>Lab on a Chip</category>
  <category>Point of Care</category>
  <category>RSC Lab on a Chip</category>
  <guid>https://www.microfluidicfuture.com/blog/simbas-everything-the-blood-touches-is-our-kingdom/index.html</guid>
  <pubDate>Wed, 21 Sep 2011 00:00:00 GMT</pubDate>
</item>
</channel>
</rss>
